Isolation of $^{236}$U and $^{239,240}$Pu from seawater samples and its determination by Accelerator Mass Spectrometry
Preprint
Abstract
In this work we present and evaluate a radiochemical procedure optimised for the analysis of $^{236}$U and $^{239,240}$Pu in seawater samples by Accelerator Mass Spectrometry (AMS). The method is based on Fe(OH)$_3$ co-precipitation of actinides and uses TEVA and UTEVA extraction chromatography resins in a simplified way for the final U and Pu purification. In order to improve the performance of the method, the radiochemical yields are analysed in 1 to 10 L seawater volumes using alpha spectrometry (AS) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). Robust 80% plutonium recoveries are obtained; however, it is found that Fe(III) concentration in the precipitation solution and sample volume are the two critical and correlated parameters influencing the initial uranium extraction through Fe(OH)$_3$ co-precipitation. Therefore, we propose an expression that optimises the sample volume and Fe(III) amounts according to both the $^{236}$U and $^{239,240}$Pu concentrations in the samples and the performance parameters of the AMS facility. The method is validated for the current setup of the 1 MV AMS system (CNA, Sevilla, Spain), where He gas is used as a stripper, by analysing a set of intercomparison seawater samples, together with the Laboratory of Ion Beam Physics (ETH, Zürich, Switzerland).
Keywords
All Related Versions
- Version 1, 2025-01-17, ArXiv
- Published version: Talanta, 178, 202.
This publication has 40 references indexed in Scilit:
- First 236U data from the Arctic Ocean and use of 236U/238U and 129I/236U as a new dual tracerEarth and Planetary Science Letters, 2016
- A first transect of 236U in the North Atlantic OceanGeochimica et Cosmochimica Acta, 2014
- Uranium-236 as a new oceanic tracer: A first depth profile in the Japan Sea and comparison with caesium-137Earth and Planetary Science Letters, 2012
- A depth profile of uranium-236 in the Atlantic OceanGeochimica et Cosmochimica Acta, 2012
- Accuracy and precision of 238Pu determination at fg level by alpha spectrometry using 239Pu and 240Pu amount analyzed by ICP-MSApplied Radiation and Isotopes, 2010
- Uranium determination using atomic spectrometric techniques: An overviewAnalytica Chimica Acta, 2010
- Sequential determination of Pu and Am radioisotopes in environmental samples; a comparison of two separation proceduresApplied Radiation and Isotopes, 2007
- Separation and preconcentration of actinides by extraction chromatography using a supported liquid anion exchanger: application to the characterization of high-level nuclear waste solutionsAnalytica Chimica Acta, 1995
- Separation and preconcentration of uranium from acidic media by extraction chromatographyAnalytica Chimica Acta, 1992
- A method for the electrodeposition of actinidesNuclear Instruments and Methods in Physics Research, 1984