Intracranial EEG fluctuates over months after implanting electrodes in human brain
- 1 September 2017
- journal article
- research article
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 14 (5) , 056011
Abstract
Objective . Implanting subdural and penetrating electrodes in the brain causes acute trauma and inflammation that affect intracranial electroencephalographic (iEEG) recordings. This behavior and its potential impact on clinical decision-making and algorithms for implanted devices have not been assessed in detail. In this study we aim to characterize the temporal and spatial variability of continuous, prolonged human iEEG recordings. Approach . Intracranial electroencephalography from 15 patients with drug-refractory epilepsy, each implanted with 16 subdural electrodes and continuously monitored for an average of 18 months, was included in this study. Time and spectral domain features were computed each day for each channel for the duration of each patient’s recording. Metrics to capture post-implantation feature changes and inflexion points were computed on group and individual levels. A linear mixed model was used to characterize transient group-level changes in feature values post-implantation and independent linear models were used to describe individual variability. Main results . A significant decline in features important to seizure detection and prediction algorithms (mean line length, energy, and half-wave), as well as mean power in the Berger and high gamma bands, was observed in many patients over 100 d following implantation. In addition, spatial variability across electrodes declines post-implantation following a similar timeframe. All selected features decreased by 14–50% in the initial 75 d of recording on the group level, and at least one feature demonstrated this pattern in 13 of the 15 patients. Our findings indicate that iEEG signal features demonstrate increased variability following implantation, most notably in the weeks immediately post-implant. Significance . These findings suggest that conclusions drawn from iEEG, both clinically and for research, should account for spatiotemporal signal variability and that properly assessing the iEEG in patients, depending upon the application, may require extended monitoring.Keywords
Funding Information
- National Institutes of Health (T32NS091006, U01NS073557, U24NS063930, R01NS099348)
This publication has 47 references indexed in Scilit:
- Long-Term Measurement of Impedance in Chronically Implanted Depth and Subdural Electrodes During Responsive Neurostimulation in HumansBrain Stimulation, 2013
- High‐frequency oscillations, extent of surgical resection, and surgical outcome in drug‐resistant focal epilepsyEpilepsia, 2013
- Multiple Implants Do Not Aggravate the Tissue Reaction in Rat BrainPLOS ONE, 2012
- Pathologic Findings Associated With Invasive EEG Monitoring for Medically Intractable EpilepsyAmerican Journal of Clinical Pathology, 2012
- First long term in vivo study on subdurally implanted Micro-ECoG electrodes, manufactured with a novel laser technologyBiomedical Microdevices, 2010
- Postmortem analysis following 71 months of deep brain stimulation of the subthalamic nucleus for Parkinson diseaseJournal of Neurosurgery, 2008
- Histological Alterations Induced by Electrode Implantation and Electrical Stimulation in the Human Brain: A ReviewNeuromodulation: Technology at the Neural Interface, 2007
- Neuronal cell loss accompanies the brain tissue response to chronically implanted silicon microelectrode arraysExperimental Neurology, 2005
- Biocompatibility of silicon‐based electrode arrays implanted in feline cortical tissueJournal of Biomedical Materials Research, 1993
- Cerebellar Stimulation for Seizure Control: 17-Year StudyStereotactic and Functional Neurosurgery, 1992