Field evaluation of five volatile organic compound measurement techniques: Implications for green building decision making
Authors:
- 30 October 2014
- journal article
- research article
- Published by Taylor & Francis in Science and Technology for the Built Environment
- Vol. 21 (1) , 67-79
Abstract
Measurements of volatile organic compounds can be necessary to ensure healthy indoor environments. Many methods exist to collect and analyze volatile organic compounds, and each technique is associated with characteristic issues that affect the identification and quantification of some volatile organic compounds. In this study, simultaneous samples of volatile organic compounds were collected during 30 test visits in 14 retail stores. Time-integrated measurements were made using Summa canisters, Tenax-GR sorbent tubes, and 2,4-dinitrophenylhydrazine tubes. Time-resolved measurements were collected using photoionization detectors and colorimetric formaldehyde multimode monitors. Sampling with Summa canisters is less field intensive than with sorbent tubes; however, samples collected using Tenax-GR sorbent tubes indicated more possible exceedances of health guidelines compared to Summa canister samples. Photoionization detector total volatile organic compound concentrations were not directly correlated with Summa canister results even after correction for differential response to different volatile organic compounds. Formaldehyde monitor results were strongly correlated with 2,4-dinitrophenylhydrazine tube results for formaldehyde, and the two sampling techniques agreed on all exceedances of the National Institute for Occupational Safety and Health (NIOSH) chronic recommended exposure limit (16 ppb) but not on exceedances of the stricter Office of Environmental Health Hazard Assessment chronic recommended exposure limit (7.3 ppb) at two stores. The formaldehyde monitor showed promising characteristics, supporting its further consideration as an indicator to control ventilation and/or environmental parameters in buildings where formaldehyde concentrations are of concern. The variation in results from various volatile organic compound sampling approaches can lead to different compliance levels with green building standards for a single building.Keywords
This publication has 26 references indexed in Scilit:
- A coupled sensor-spectrophotometric device for continuous measurement of formaldehyde in indoor environmentsJournal of Exposure Science & Environmental Epidemiology, 2013
- Evaluation of the Indoor Air Quality Procedure for Use in Retail Buildings2013
- Sustainable and healthy buildingsEnergy and Buildings, 2012
- Organic compounds as indicators of air pollutionIndoor Air, 2002
- Sorbent trapping of volatile organic compounds from airJournal of Chromatography A, 2000
- Field Evaluation of a Portable Photoionization Detector for Assessing Exposure to Solvent MixturesAIHA Journal, 2000
- Field Investigation Comparing Diffusion Badge and Charcoal Tube Monitoring for StyreneApplied Occupational and Environmental Hygiene, 2000
- Analysis and stability of aldehydes and terpenes in electropolished canistersAtmospheric Environment, 1998
- Viability of Using SUMMA Polished Canisters for the Collection and Storage of Parts per Billion by Volume Level Volatile OrganicsEnvironmental Science & Technology, 1995
- Indoor air pollution due to chipboard used as a construction materialAtmospheric Environment (1967), 1975