Visual function comparison of 2 aspheric multifocal intraocular lenses
Authors:
- José F. AlfonsoJAJosé F. Alfonso
- Luis Fernández-VegaLFLuis Fernández-Vega
- José I. BlázquezJBJosé I. Blázquez
- Robert Montés-MicóRMRobert Montés-Micó
- 1 February 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 38 (2) , 242-248
Abstract
To compare visual function after bilateral implantation of the multifocal Lentis Mplus LS-312 with a nonrotational symmetrical design (copolymer aspheric) or the Acrysof Restor SN6AD1 +3.0 D (hybrid aspheric) intraocular lens (IOL). Fernández-Vega Ophthalmological Institute, Oviedo, Spain. Comparative case series. Six months postoperatively, corrected distance visual acuity (CDVA), distance-corrected near visual acuity (DCNVA), the defocus curve, and photopic and mesopic contrast sensitivity with and without glare were measured. The mean CDVA was 0.02 ± 0.06 (SD) with the copolymer aspheric IOL and -0.06 ± 0.05 logMAR with the hybrid aspheric IOL (P=.07) and the mean DCNVA, 0.10 ± 0.06 and -0.09 ± 0.06 logMAR, respectively. The DCNVA was better with the hybrid aspheric IOL (P<.05). The defocus curve showed that the hybrid aspheric IOL provided better visual acuity from 0.00 to -5.00 diopter (D) vergences (P<.05) except for -1.00 and -1.50 D, where the IOLs were comparable. Contrast sensitivity was better with the hybrid aspheric IOL at 12 cycles per degree (cpd) and 18 cpd under photopic conditions (P<.05). No significant differences were found under mesopic conditions (P>.05). Both IOL models gave good and comparable visual acuity at distance. However, the hybrid aspheric IOL provided better DCNVA than the copolymer aspheric IOL. Intermediate vision was not as good as distance and near and was similar between the 2 IOLs. Photopic contrast sensitivity was better with the hybrid aspheric IOL at high spatial frequencies and comparable between IOLs at low frequencies and under mesopic conditions.Keywords
This publication has 30 references indexed in Scilit:
- Apodized diffractive versus refractive multifocal intraocular lenses: Optical and visual evaluationJournal of Cataract & Refractive Surgery, 2008
- Prospective functional and clinical comparison of bilateral ReZoom and ReSTOR intraocular lenses in patients 70 years or youngerJournal of Cataract & Refractive Surgery, 2008
- Symmetric bilateral implantation of a distance-dominant diffractive bifocal intraocular lensJournal of Cataract & Refractive Surgery, 2007
- Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens systemJournal of Cataract & Refractive Surgery, 2007
- European Multicenter Study of the AcrySof ReSTOR Apodized Diffractive Intraocular LensOphthalmology, 2006
- Contrast sensitivity function in eyes with diffractive bifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2005
- Visual performance with multifocal intraocular lensesOphthalmology, 2004
- Distance and near contrast sensitivity function after multifocal intraocular lens implantationJournal of Cataract & Refractive Surgery, 2003
- A Prospective Evaluation of a Diffractive versus a Refractive Designed Multifocal Intraocular LensOphthalmology, 1997
- Food and Drug Administration Study UpdateOphthalmology, 1993