A Simple Method to Estimate Muscle Currents from HD-sEMG and MRI using Electrical Network and Graph Theory
Authors:
- 1 July 2019
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2019, 2657-2662
Abstract
In the last years the spread of hand prosthetics has fueled the research on the field of signal processing applied on physiologic data. At the state of the art there are different algorithms that allow a precise estimation of hand movements, the majority of whom work just on the electrode space. Even though there are signal processing methods that access single muscle information, they are still premature for a real application on prosthetics. We present a novel method that exploit the information extracted from a magnetic resonance image (MRI) and a single row of high-density surface electromyography (HD-sEMG) electrodes to estimate the muscles currents in the forearm, providing a first experimental application on two simple wrist movements to assess its performance. The results show that the proposed method is able to identify the correct muscle with a single muscle-contraction task, whereas for a 2 muscle task it shows a high variance in the results. The method models the signal propagation from muscles to electrodes using a simple resistive electrical network and uses the graph theory to calculate the muscle currents. It brings a considerably simpler muscle’s current estimation method, significantly decreasing the problem complexity, and therefore becoming a potential effective approach for future prosthetics’ control.Keywords
This publication has 11 references indexed in Scilit:
- Decoding Motor Unit Activity From Forearm Muscles: Perspectives for Myoelectric ControlIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2017
- Control Capabilities of Myoelectric Robotic Prostheses by Hand Amputees: A Scientific Research and Market OverviewFrontiers in Systems Neuroscience, 2015
- The ImageJ ecosystem: An open platform for biomedical image analysisMolecular Reproduction and Development, 2015
- Current state of digital signal processing in myoelectric interfaces and related applicationsBiomedical Signal Processing and Control, 2015
- Electromagnetic Brain Imaging2015
- An EMG-CT method using multiple surface electrodes in the forearmJournal of Electromyography and Kinesiology, 2014
- An empirical Bayesian solution to the source reconstruction problem in EEGNeuroImage, 2005
- Volume Conduction in an Anatomically Based Surface EMG ModelIEEE Transactions on Biomedical Engineering, 2004
- Influence of anatomical, physical, and detection-system parameters on surface EMGBiological Cybernetics, 2002
- Lead-field Bases for Electroencephalography Source ImagingAnnals of Biomedical Engineering, 2000