Application of New Shield Structure for Shaft Voltage Reduction in IPMSM
Authors:
- 29 October 2023
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 4442-4445
Abstract
The interior permanent magnet synchronous motor (IPMSM) driven by the PWM inverter generates a shaft voltage by the common mode voltage (CMV). Therefore, this shaft voltage causes a fault in the motor. This paper proposes a method of reducing shaft voltage by applying a copper shield of a new structure in IPMSM. First, an equivalent circuit model considering the parasitic capacitance of the motor is analyzed. Second, a new structure of copper shield to reduce shaft voltage is analyzed. Third, the shaft voltage reduction effect through the copper shield is analyzed by experiment, and the simulation and experiment are compared and verified.Keywords
Funding Information
- Korea Evaluation Institute of Industrial Technology
- Korea Evaluation Institute of Industrial Technology
This publication has 4 references indexed in Scilit:
- Shaft-to-Frame Voltage Mitigation Method by Changing Winding-to-Rotor Parasitic Capacitance of IPMSMIEEE Transactions on Industry Applications, 2018
- New Equivalent Circuit of the IPM-Type BLDC Motor for Calculation of Shaft Voltage by Considering Electric and Magnetic FieldsIEEE Transactions on Industry Applications, 2016
- Model Predictive Control Methods to Reduce Common-Mode Voltage for Three-Phase Voltage Source InvertersIEEE Transactions on Power Electronics, 2014
- A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction MotorsIEEE Transactions on Industry Applications, 2010