Automatic assessment of human gastric motility and emptying from dynamic 3D magnetic resonance imaging
- 24 August 2021
- journal article
- research article
- Published by Wiley in Neurogastroenterology & Motility
- Vol. 34 (1) , e14239
Abstract
Background: Time‐sequenced magnetic resonance imaging (MRI) of the stomach is an emerging technique for non‐invasive assessment of gastric emptying and motility. However, an automated and systematic image processing pipeline for analyzing dynamic 3D (ie, 4D) gastric MRI data has not been established. This study uses an MRI protocol for imaging the stomach with high spatiotemporal resolution and provides a pipeline for assessing gastric emptying and motility.Methods: Diet contrast‐enhanced MRI images were acquired from seventeen healthy humans after they consumed a naturalistic contrast meal. An automated image processing pipeline was developed to correct for respiratory motion, to segment and compartmentalize the lumen‐enhanced stomach, to quantify total gastric and compartmental emptying, and to compute and visualize gastric motility on the luminal surface of the stomach.Key Results: The gastric segmentation reached an accuracy of 91.10 ± 0.43% with the Type‐I error and Type‐II error being 0.11 ± 0.01% and 0.22 ± 0.01%, respectively. Gastric volume decreased 34.64 ± 2.8% over 1 h where the emptying followed a linear‐exponential pattern. The gastric motility showed peristaltic patterns with a median = 4 wave fronts (range 3–6) and a mean frequency of 3.09 ± 0.07 cycles per minute. Further, the contractile amplitude was stronger in the antrum than in the corpus (antrum vs. corpus: 5.18 ± 0.24 vs. 3.30 ± 0.16 mm;p < 0.001).Conclusions & Inferences: Our analysis pipeline can process dynamic 3D MRI images and produce personalized profiles of gastric motility and emptying. It will facilitate the application of MRI for monitoring gastric dynamics in research and clinical settings.Keywords
All Related Versions
This publication has 39 references indexed in Scilit:
- Technique of Functional and Motility Test: How to Perform Antroduodenal ManometryJournal of Neurogastroenterology and Motility, 2013
- Comparison of calculations to estimate gastric emptying half‐time of solids in humansNeurogastroenterology & Motility, 2012
- Spurious but systematic correlations in functional connectivity MRI networks arise from subject motionNeuroImage, 2012
- Manganese-based MRI contrast agents: past, present, and futureTetrahedron, 2011
- Assessment of gastrointestinal motor functions by MRI: a comprehensive reviewNeurogastroenterology & Motility, 2011
- Origin and propagation of human gastric slow-wave activity defined by high-resolution mappingAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2010
- MRI for the evaluation of gastric physiologyEuropean Radiology, 2010
- Effect of meal volume and calorie load on postprandial gastric function and emptying: studies under physiological conditions by combined fiber-optic pressure measurement and MRIAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2009
- Consensus Recommendations for Gastric Emptying Scintigraphy: A Joint Report of the American Neurogastroenterology and Motility Society and the Society of Nuclear MedicineJournal of Nuclear Medicine Technology, 2008
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986