Influence of on-load voltage distortion on torque-speed characteristic of interior permanent magnet machines
Authors:
- 1 September 2015
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23293721,p. 760-767
Abstract
The on-load voltage distortion in interior permanent magnet (IPM) machine refers to the terminal voltage distorted by armature reaction. In this paper, the mechanism of the on-load voltage distortion have been investigated with the aid of frozen permeability method based on both fractional and integer slot IPM machines. It reveals that the local magnetic saturation caused by armature reaction will distort the on-load back-EMFs and dq-axis inductances, which consequently leads to terminal voltage distortion. Due to the geometric feature of IPM rotors, the armature reaction fluxes become more difficult to circulate with the increase of current angle, which further enhances the fluctuation of dq-axis inductances and is found to be the main reason for the terminal voltage distortion in flux weakening operations. Then, the variations of both on-load back-EMFs and dq-axis inductances due to armature reaction are investigated. Consequently, the torque ripples under different current angles are analysed. Meanwhile, the flux weakening performances under fixed DC link voltages are also calculated, which shows the terminal voltage distortion may largely reduce the flux weakening operation region and cause the control of the drive system difficulty. Finally, a 42-slot/8-pole IPM machine is tested to validate the analyses, which also reveals that the phase currents would be distorted if ignoring the peak voltage caused by on-load voltage distortion.Keywords
This publication has 12 references indexed in Scilit:
- Torque Analysis of Interior Permanent-Magnet Synchronous Motors by Considering Cross-Magnetization: Variation in Torque Components With Permanent-Magnet ConfigurationsIEEE Transactions on Industrial Electronics, 2013
- Analysis of harmonic contents in induced voltage and electromagnetic torque in interior permanent magnet synchronous machines under loaded condition2013
- Comparison of Interior and Surface PM Machines Equipped With Fractional-Slot Concentrated Windings for Hybrid Traction ApplicationsIEEE Transactions on Energy Conversion, 2012
- Winding Inductances of an Interior Permanent Magnet (IPM) Machine With Fractional Slot Concentrated WindingIEEE Transactions on Magnetics, 2012
- MMF Harmonics Effect on the Embedded FE Analytical Computation of PM MotorsIEEE Transactions on Industry Applications, 2010
- Fractional-Slot Concentrated-Windings Synchronous Permanent Magnet Machines: Opportunities and ChallengesIEEE Transactions on Industrial Electronics, 2009
- Influence of Skew and Cross-Coupling on Flux-Weakening Performance of Permanent-Magnet Brushless AC MachinesIEEE Transactions on Magnetics, 2009
- Magnetic models of saturated interior permanent magnet motors based on finite element analysis2002
- Improved modulation techniques for PWM-VSI drivesIEEE Transactions on Industrial Electronics, 1997
- Field-weakening performance of brushless synchronous AC motor drivesIEE Proceedings - Electric Power Applications, 1994