Remote monitoring of cardiac implantable devices in the Asia-Pacific
Authors:
Open Access
- 1 June 2013
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 15 (suppl 1) , i65-i68
Abstract
Remote monitoring of pacemakers and implantable cardioverter defibrillators (ICDs) has emerged as a tool to replace regular follow-up of such devices, and to detect hardware failure, arrhythmias, and heart failure decompensation. The Asia-Pacific region is a geographically diverse area, with widely different cardiac device implant rates and expertise. However, common to all countries, distance and logistic for patients to reach an expert monitoring centre for routine follow up are significant, and in some countries, this will likely be replaced by remote monitoring. Unscheduled visits such as for the treatment of atrial fibrillation and ICD shocks will be expedited. There has been an increase in both pacemaker and ICD implant rates in Asia-Pacific, due to an ageing population and improvement in economic condition. Among the countries, Australia and Japan are the major users of remote monitoring. According to the statistics of the suppliers, in Australia, up to 15% of pacemakers, 40% ICD, and 30% cardiac resynchronization therapy (CRT)/cardiac resynchronization therapy defibrillator (CTRD) are remotely monitored. The corresponding numbers for Japan are 5, 50, and 50% respectively. The monitoring personnel include nurses, technicians, and doctors, either from local centre or from device companies. Cost, lack of reimbursement, and logistic support are major issues in widespread application of remote monitoring technology. In conclusion, remote monitoring is increasing in Asia-Pacific region despite the increase in cost. Implantable cardioverter defibrillators and CRT/CRTDs are more likely than pacemakers to be enabled with remote monitoringKeywords
This publication has 11 references indexed in Scilit:
- Remote Monitoring Reduces Healthcare Use and Improves Quality of Care in Heart Failure Patients With Implantable DefibrillatorsCirculation, 2012
- Subclinical Atrial Fibrillation and the Risk of StrokeNew England Journal of Medicine, 2012
- Intrathoracic Impedance Monitoring, Audible Patient Alerts, and Outcome in Patients With Heart FailureCirculation, 2011
- The 11th World Survey of Cardiac Pacing and Implantable Cardioverter‐Defibrillators: Calendar Year 2009–A World Society of Arrhythmia's ProjectPacing and Clinical Electrophysiology, 2011
- Are MADIT II Criteria for Implantable Cardioverter Defibrillator Implantation Appropriate for Chinese Patients?Journal of Cardiovascular Electrophysiology, 2010
- Multicenter randomized study of anticoagulation guided by remote rhythm monitoring in patients with implantable cardioverter-defibrillator and CRT-D devices: Rationale, design, and clinical characteristics of the initially enrolled cohortAmerican Heart Journal, 2009
- Smoking, diabetes and cardiovascular diseases in men in the Asia Pacific regionJournal of Diabetes, 2009
- HRS/EHRA Expert Consensus on the Monitoring of Cardiovascular Implantable Electronic Devices (CIEDs): Description of Techniques, Indications, Personnel, Frequency and Ethical ConsiderationsDeveloped in partnership with the Heart Rhythm Society (HRS) and the European Heart Rhythm Association (EHRA); and in collaboration with the American College of Cardiology (ACC), the American Heart Association (AHA), the European Society of Cardiology (ESC), the Heart Failure Association of ESC (HFA), and the Heart Failure Society of America (HFSA). Endorsed by the Heart Rhythm Society, the European Heart Rhythm Association (a registered branch of the ESC), the American College of Cardiology, the American Heart AssociationEP Europace, 2008
- The impact of reimbursement on the usage of pacemakers, implantable cardioverter defibrillators and radiofrequency ablationJournal of Interventional Cardiac Electrophysiology, 2006
- Are the MADIT II Criteria for ICD Implantation Appropriate for Japanese Patients?Circulation Journal, 2005