Implementation and Effectiveness of a Bar Code–Based Transfusion Management System for Transfusion Safety in a Tertiary Hospital: Retrospective Quality Improvement Study
Open Access
- 26 August 2019
- journal article
- research article
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 7 (3) , e14192
Abstract
Background: Large-scale and long-term studies are not sufficient to determine the efficiency that IT solutions can bring to transfusion safety. Objective: This quality-improvement report describes our continuous efforts to implement and upgrade a bar code–based transfusion management (BCTM) system since 2011 and examines its effectiveness and sustainability in reducing blood transfusion errors, in a 3000-bed tertiary hospital, where more than 60,000 prescriptions of blood transfusion are covered by 2500 nurses each year. Methods: The BCTM system uses barcodes for patient identification, onsite labeling, and blood product verification, through wireless connection to the hospital information systems. Plan-Do-Study-Act (PDSA) cycles were used to improve the process. Process maps before and after implementation of the BCTM system in 2011 were drawn to highlight the changes. The numbers of incorrect labeling or wrong blood in tube incidents that occurred quarterly were plotted on a run chart to monitor the quality changes of each intervention introduced. The annual occurrences of error events from 2011 to 2017 were compared with the mean occurrence of 2008-2010 to determine whether implementation of the BCTM system could effectively reduce the number of errors in 2016 and whether this reduction could persist in 2017. Results: The error rate decreased from 0.03% in 2008-2010 to 0.002% in 2016 (P<.001) and 0.001% in 2017 (P<.001) after implementation of the BTCM system. Only one incorrect labeling incident was noted among the 68,324 samples for blood typing, and no incorrect transfusions occurred among 67,423 transfusion orders in 2017. Conclusions: This report demonstrates that continuous efforts to upgrade the existing process is critical to reduce errors in transfusion therapy, with support from information technology.Keywords
This publication has 18 references indexed in Scilit:
- Blood transfusion: patient identification and empowermentBritish Journal of Nursing, 2016
- The Efficacy of Patients’ Wristband Bar-code on Prevention of Medical ErrorsApplied Clinical Informatics, 2015
- Wrong blood in tube – potential for serious outcomes: can it be prevented?British Journal of Haematology, 2014
- Interventions to Reduce Wrong Blood in Tube Errors in Transfusion: A Systematic ReviewTransfusion Medicine Reviews, 2013
- Serious Hazards of Transfusion (SHOT) haemovigilance and progress is improving transfusion safetyBritish Journal of Haematology, 2013
- Effectiveness of barcoding for reducing patient specimen and laboratory testing identification errors: A Laboratory Medicine Best Practices systematic review and meta-analysisClinical Biochemistry, 2012
- Patient involvement in blood transfusion safety: patients' and healthcare professionals' perspectiveTransfusion Medicine, 2012
- Transfusion practice and safety: current status and possibilities for improvementVox Sanguinis, 2010
- Improving transfusion safety: implementation of a comprehensive computerized bar code–based tracking system for detecting and preventing errorsTransfusion, 2008