Oral rehabilitation using Camlog® screw–cylinder implants with a particle‐blasted and acid‐etched microstructured surface. Results from a prospective study with special consideration of short implants
- 21 June 2007
- journal article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 18 (5) , 591-600
Abstract
Objectives: The purpose of the present clinical study was to report on the clinical performance of screw–cylinder implants with special consideration of the survival rate of short implants. Material and methods: In this prospective study with consecutive patient recruitment, Camlog® screw–cylinder implants with a particle‐blasted and acid‐etched microstructured surface and a triple‐cam tube‐in‐tube implant‐abutment connection have been used only. Two groups of implants were evaluated: implants of 9 and 11 mm in length were considered short, those of 13 and 16 mm were considered long. Besides clinical and radiographic parameters, data of complications, patients' subjective evaluation of treatment outcome, general medical history and smoking habits were recorded. Results: Three hundred and thirty‐three Camlog® screw–cylinder implants were inserted in 133 patients. One hundred and twenty‐nine patients were available for follow‐up, representing 325 implants. The median observation period was 33 months (Q25% 26; Q75% 38). After a maximum observation period of 55 months, the Kaplan–Meier‐survival analysis revealed no significant difference between the mean survival probabilities of 98.3% (n=59, patient‐related) of short implants, and of 95.7% of long implants (n=70, patient‐related) (P=0.162). No significant difference was found between implant survival rates considering maxilla (98.7%) and mandible (98.2%). A stratified analysis of short implants revealed a significant influence of premature cover screw exposures (P=0.02) and smoking (P=0.008) on implant survival. These influences were not found significant for long implants. Conclusions: The prognosis of short Camlog® implants is comparable with that of long implants. Therefore, their clinical use instead of performance of sophisticated vertical augmentation procedures before installation of long implants might be considered as alternative treatment option. In smokers, the use of short implants should be considered cautiously, however. The risk of premature cover screw exposure should be minimized.Keywords
This publication has 26 references indexed in Scilit:
- A 7‐year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implantsClinical Oral Implants Research, 2004
- Early loading (2 or 6 weeks) of sandblasted and acid‐etched (SLA) ITI® implants in the posterior mandibleClinical Oral Implants Research, 2004
- Imaging of periimplant bone levels of implants with buccal bone defectsClinical Oral Implants Research, 2003
- Biologic outcome of implant‐supported restorations in the treatment of partial edentulismClinical Oral Implants Research, 2002
- Observations on a New Collagen Barrier Membrane in 16 Consecutively Treated Patients. Clinical and Histological FindingsJournal of Periodontology, 2001
- Long‐term evaluation of non‐submerged ITI implants. Part 1: 8‐year life table analysis of a prospective multi‐center study with 2359 implants.Clinical Oral Implants Research, 1997
- Retrospective multicenter analysis of 3i endosseous dental implants placed over a five‐year periodClinical Oral Implants Research, 1996
- Fixture design and overload influence marginal bone loss and future success in the Brånemark® systemClinical Oral Implants Research, 1992
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958
- Nonparametric Estimation from Incomplete ObservationsJournal of the American Statistical Association, 1958