Effects of Noise, Nonlinear Processing, and Linear Filtering on Perceived Speech Quality
- 1 June 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Ear & Hearing
- Vol. 31 (3) , 420-436
Abstract
Objectives: The purpose of this study was to measure subjective quality ratings in listeners with normal hearing and listeners with hearing loss for speech subjected to a wide range of processing conditions that are representative of real hearing aids. Design: Speech quality was assessed using a rating scale in a group of 14 listeners with normal hearing and 15 listeners with mild to moderately severe sensorineural hearing loss. Controlled simulations of hearing aid processing were used to process speech that included speech subjected to (1) noise and nonlinear processing, (2) linear filtering, and (3) combinations of noise, nonlinear processing, and linear filtering. The 32 conditions of noise and nonlinear processing included stationary speech-shaped nose, multitalker babble, peak clipping, quantization noise, spectral subtraction, and dynamic range compression (in quiet, with babble, and with spectral subtraction). The 32 linear filtering conditions included high-pass filtering, low-pass filtering, band-pass filtering, positive and negative spectral tilt, and resonance peaks. Subsets of these conditions were used for the 36 conditions that combined noise and nonlinear processing with linear processing. Results: Both listeners with normal hearing and listeners with hearing loss gave consistent (reliable) ratings. In both listener groups, sound quality was significantly affected by the noise, nonlinear processing, and linear filtering conditions. Compared with the listeners with normal hearing, the listeners with hearing loss showed significantly lower ratings of sound quality in nearly all of the processing conditions. For the conditions included in the current hearing aid simulation, noise and nonlinear conditions had a greater effect on quality judgments than did the linear filtering conditions. Conclusions: The data reported here provide a comprehensive dataset of speech quality ratings for simulated hearing aid processing conditions. The results indicate that quality ratings by listeners with hearing loss are significantly lower than quality ratings by listeners with normal hearing. In addition, quality ratings by listeners with hearing loss are impacted by signal processing at least as much as, and often more than, the quality ratings by listeners with normal hearing. Finally, quality ratings for speech processed with a simulated hearing aid are impacted more by noise and nonlinear signal processing than by linear filtering.Keywords
This publication has 42 references indexed in Scilit:
- Speech and Music Quality Ratings for Linear and Nonlinear Hearing Aid CircuitryJournal of the American Academy of Audiology, 2007
- Effects of noise and distortion on speech quality judgments in normal-hearing and hearing-impaired listenersThe Journal of the Acoustical Society of America, 2007
- PresbycusisThe Lancet, 2005
- Preference for and Performance With Damped and Undamped Hearing Aids by Listeners With Sensorineural Hearing LossJournal of Speech, Language, and Hearing Research, 1996
- Loudspeaker frequency response and perceived sound qualityThe Journal of the Acoustical Society of America, 1991
- Perceived sound quality of reproductions with different frequency responses and sound levelsThe Journal of the Acoustical Society of America, 1990
- The Effects of Different Frequency Responses on Sound Quality Judgments and Speech IntelligibilityJournal of Speech, Language, and Hearing Research, 1988
- Development of the Connected Speech Test (CST)Ear & Hearing, 1987
- The National Acoustic Laboratoriesʼ (NAL) New Procedure for Selecting the Gain and Frequency Response of a Hearing AidEar & Hearing, 1986
- Perceived sound quality of sound-reproducing systemsThe Journal of the Acoustical Society of America, 1979