Comparison of Two Wavefront Autorefractors: Binocular Open-Field versus Monocular Closed-Field
Open Access
- 3 January 2020
- journal article
- research article
- Published by Wiley in Journal of Ophthalmology
- Vol. 2020, 1-10
Abstract
Purpose. To evaluate the agreement and repeatability between a new commercially available binocular open-field wavefront autorefractor, as part of the Eye Refract system, and a monocular closed-field wavefront autorefractor (VX110). Methods. A cross-sectional, randomized, and single-masked study was performed. Ninety-nine eyes of 99 healthy participants (37.22 ± 18.04 years, range 8 to 69 years) were randomly analyzed. Three measurements with the Eye Refract and the VX110 were taken on three different days, under noncycloplegic conditions. Mean spherical equivalent (MSE), cylindrical vectors (J0 and J45), and binocular corrected distance visual acuity (BCDVA) were compared between both autorefractors. An intersession repeatability analysis was done considering the values of repeatability (Sr) and its 95% limit (r). Results. The VX110 showed more negative values () in terms of MSE in comparison with the Eye Refract (0.20 D). Regarding cylindrical vectors, J45 showed statistically significant differences () between both wavefront autorefractors, but they were not clinically relevant (<0.05 D). In BCDVA, there were no statistically significant differences () between both wavefront autorefractors. Additionally, the Eye Refract was more repeatable than the VX110 in terms of both MSE (SrEYE REFRACT = 0.21 D, SrVX110 = 0.53 D) and J0 (SrEYE REFRACT = 0.12 D, SrVX110 = 0.35 D). Conclusions. The Eye Refract provided enough accuracy and reliability to estimate refractive errors in different age groups, achieving better results than the VX110. Therefore, the Eye Refract proved to be a useful autorefractor to be incorporated into clinical practice.
Keywords
Funding Information
- Universidad Complutense de Madrid
This publication has 43 references indexed in Scilit:
- Evaluation of the auto‐refraction function of the Nidek OPD‐Scan IIIClinical and Experimental Optometry, 2014
- Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500Ophthalmic and Physiological Optics, 2010
- Evaluation of Image Quality Metrics for the Prediction of Subjective Best FocusOptometry and Vision Science, 2010
- Accuracy of WASCA Aberrometer Refraction Compared to Manifest Refraction in Chinese Adult MyopesJournal of Refractive Surgery, 2009
- Diagnostic accuracy and variability of autorefraction by the Tracey Visual Function Analyzer and the Shin‐Nippon NVision‐K 5001 in relation to subjective refractionOphthalmic and Physiological Optics, 2009
- Influence of fogging lenses and cycloplegia on open‐field automatic refractionOphthalmic and Physiological Optics, 2008
- A Comparison of Autorefraction and Subjective Refraction With and Without Cycloplegia in Primary School ChildrenAmerican Journal of Ophthalmology, 2006
- Measurement of Refractive Errors in Young Myopes Using the COAS Shack-Hartmann AberrometerOptometry and Vision Science, 2003
- Clinical evaluation of the Shin-Nippon SRW-5000 autorefractor in adultsOphthalmic and Physiological Optics, 2001
- How is binocularity maintained during convergence and divergence?Eye, 1996