Diagnostic performance of rapid antigen testing for SARS-CoV-2: the COVid-19 AntiGen (COVAG) extension study
Open Access
- 16 April 2024
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Medicine
- Vol. 11, 1352633
Abstract
Background: This study is the extension of the COVAG study. We compared two RATs, the Panbio COVID-19 Ag Rapid Test (Abbott) and the SD Biosensor Q SARS-CoV-2 Rapid Antigen Test (Roche), against RT-PCR on the foil of new variants.Methods: We included 888 all-comers at a diagnostic center between October 20, 2021, and March 18, 2022. RT-PCR-positive samples with a Ct value ≤32 were examined for SARS-CoV-2 variants.Findings: The sensitivity of the Abbott-RAT and Roche-RAT were 65 and 67%, respectively. For both RATs, lower Ct values were significantly correlated with higher sensitivity. For samples with Ct values ≤25, the sensitivities of the Roche-RAT and of the Abbott-RAT were 96 and 95%, for Ct values 25–30 both were 19%, and for Ct values ≥30 they were 6 and 2%, respectively. The RATs had substantially higher sensitivities in symptomatic than asymptomatic participants (76, 77%, vs. 29, 31%, for Abbott-RAT, Roche-RAT, respectively) and in participants referred to testing by their primary care physician (84, 85%) compared to participants who sought testing due to referral by the health department (55, 58%) or a warning by the Corona-Warn-App (49, 49%). In persons with self-reported previous COVID-19 sensitivities were markedly lower than in patients without previous COVID-19: 27% vs. 75% for Roche-RAT and 27% vs. 73% for Abbott-RAT. We did not find significant correlation between vaccination status and sensitivity. The Omicron variant was detected with a sensitivity of 94 and 92%, the delta variant with a sensitivity of 80 and 80% for Abbott-RAT and Roche-RAT, respectively. This difference is attributable to the lower Ct values of the Omicron samples compared to the Delta samples. When adjusted for the Ct value, a multivariate logistic regression did not show a significant difference between Omicron and Delta. In terms of sensitivity, we found no significant difference between the wild-type and the Omicron and Delta variants, but a significantly lower sensitivity to the alpha variant compared to the other variants.The specificities were > 99% overall.Keywords
This publication has 23 references indexed in Scilit:
- Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infectionCochrane Database of Systematic Reviews, 2022
- Viral load of SARS‐CoV‐2 Omicron is not high despite its high infectivityJournal of Medical Virology, 2022
- SARS-CoV-2 variants, immune escape, and countermeasuresFrontiers of Medicine, 2022
- Impaired detection of omicron by SARS-CoV-2 rapid antigen testsMedical Microbiology and Immunology, 2022
- Serial antigen rapid testing in staff of a large acute hospitalThe Lancet Infectious Diseases, 2021
- Nucleocapsid mutations R203K/G204R increase the infectivity, fitness, and virulence of SARS-CoV-2Cell Host & Microbe, 2021
- Evaluation of five widely used serologic assays for antibodies to SARS-CoV-2Diagnostic Microbiology and Infectious Disease, 2021
- Rapid, point-of-care antigen tests for diagnosis of SARS-CoV-2 infectionCochrane Database of Systematic Reviews, 2021
- Antibody tests for identification of current and past infection with SARS-CoV-2Cochrane Database of Systematic Reviews, 2020
- Clinical course and risk factors for mortality of adult inpatients with COVID-19 in Wuhan, China: a retrospective cohort studyThe Lancet, 2020