3D-MRI of the Ankle With Optimized 3D-SPACE
- 1 April 2012
- journal article
- research article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 47 (4) , 231-239
Abstract
Purpose: To assess the use of 3-dimensional (3D) MR imaging of the ankle with the 3D-turbo-spin-echo-sequence 3D-“Sampling Perfection with Application optimized Contrast using different flip angle Evolutions” (SPACE), as compared with 2-dimensional-turbo-spin-echo-sequence. Material and Methods: After internal review board's approval and informed consent, 15 healthy volunteers and 45 consecutive patients were examined at 3 T with isotropic fat-saturated moderately T2-weighted 3D-SPACE (voxel size: 0.63 mm3/acquisition time: 6:43 minutes) featuring radial k-space reordering for optimized contrast. Signal- and contrast-to-noise ratios (SNR; CNR, respectively) were calculated with the subtraction method. Using free 3D reconstructions, 2 radiologists independently assessed depiction of cartilage, ligaments, and tendons, as well as detection and grading of abnormalities of these structures (5-point Likert scale) compared with conventional 2-dimensional-TSE-sequences (voxel size: 0.4 × 0.4 × 3 mm3/total acquisition time: 11 minutes). Statistical analysis was performed with Wilcoxon signed rank tests, 95% and 99% confidence intervals and weighted κ coefficients. Results: SNR and CNR of fluid/cartilage were significantly higher for 3D-SPACE (P < 0.05). The isotropic voxel size facilitated improved depiction of the medial and lateral ankle ligaments with significant differences for the calcaneofibular ligament and the anteromedial ligament complex (P < 0.05). In the patient cohort, cartilage and spring ligaments were also significantly better depicted (P < 0.05). However, there were no significant differences in the number or in the diagnostic confidence of detected cartilage, ligament, or tendon abnormalities. Interreader correlation was good (κ = 0.69–0.71) for both sequences. The correlation between the 2 sequences was excellent (κ = 0.84–0.85). Conclusion: 3D-SPACE allows 3D acquisition and assessment of the ankle and facilitates depiction of the complex ankle anatomy at sufficient SNR and CNR.Keywords
This publication has 25 references indexed in Scilit:
- Imaging of the Musculoskeletal System In Vivo Using Ultra-high Field Magnetic Resonance at 7 TInvestigative Radiology, 2009
- MRI of the Knee at 3TInvestigative Radiology, 2009
- Ankle: Isotropic MR Imaging with 3D-FSE-Cube—Initial Experience in Healthy VolunteersRadiology, 2008
- Isotropic MRI of the Knee with 3D Fast Spin-Echo Extended Echo-Train Acquisition (XETA): Initial ExperienceAmerican Journal of Roentgenology, 2007
- Medial Collateral Ligament Complex of the Ankle: MR Appearance in Asymptomatic SubjectsRadiology, 2007
- Improved visualization of collateral ligaments of the ankle: multiplanar reconstructions based on standard 2D turbo spin-echo MR imagesEuropean Radiology, 2006
- Magnetic Resonance Imaging of the Body Trunk Using a Single-Slab, 3-Dimensional, T2-weighted Turbo-Spin-Echo Sequence With High Sampling Efficiency (SPACE) for High Spatial Resolution ImagingInvestigative Radiology, 2005
- MR Imaging of the Ankle and FootRadioGraphics, 2000
- Optimized Single-Slab Three-dimensional Spin-Echo MR Imaging of the BrainRadiology, 2000
- The sensitivity of low flip angle RARE imagingMagnetic Resonance in Medicine, 1997