A new approach of three-dimensional guidance in paediatric cath lab: segmented and tessellated heart models for cardiovascular interventions in CHD
- 18 January 2018
- journal article
- research article
- Published by Cambridge University Press (CUP) in Cardiology in the Young
- Vol. 28 (5) , 661-667
Abstract
Background: Optimal imaging is essential for catheter-based interventions in CHD. The three-dimensional models in volume-rendering technique currently in use are not standardised. This paper investigates the feasibility and impact of novel three-dimensional guidance with segmented and tessellated three-dimensional heart models in catheterisation of CHD. In addition, a nearly radiation-free two- to three-dimensional registration and a biplane overlay were used.Methods and results: We analysed 60 consecutive cases in which segmented tessellated three-dimensional heart models were merged with live fluoroscopy images and aligned using the tracheal bifurcation as a fiducial mark. The models were generated from previous MRI or CT by dedicated medical software. We chose the stereo-lithography format, as this promises advantage over volume-rendering-technique models regarding visualisation. Prospects, potential benefits, and accuracy of the two- to three-dimensional registration were rated separately by two paediatric interventionalists on a five-point Likert scale. Fluoroscopy time, radiation dose, and contrast dye consumption were evaluated. Over a 10-month study period, two- to three-dimensional image fusion was applied to 60 out of 354 cases. Of the 60 catheterisations, 73.3% were performed in the context of interventions. The accuracy of two- to three-dimensional registration was sufficient in all cases. Three-dimensional guidance was rated superior to conventional biplane imaging in all 60 cases. We registered significantly smaller amounts of used contrast dye (p<0.01), lower levels of radiation dose (p<0.02), and less fluoroscopy time (p<0.01) during interventions concerning the aortic arch compared with a control group.Conclusions: Two- to three-dimensional image fusion can be applied successfully in most catheter-based interventions of CHD. Meshes in stereo-lithography format are accurate and base for standardised and reproducible three-dimensional models.Keywords
This publication has 19 references indexed in Scilit:
- Multimodality 3D‐roadmap for cardiovascular interventions in congenital heart disease—A single‐center, retrospective analysis of 78 casesCatheterization and Cardiovascular Interventions, 2012
- 3‐D guidance of complex pulmonary artery stent placement using reconstructed rotational angiography with live overlayCatheterization and Cardiovascular Interventions, 2011
- The value of flat-detector computed tomography during catheterisation of congenital heart diseaseEuropean Radiology, 2011
- X-Ray Magnetic Resonance Fusion to Internal Markers and Utility in Congenital Heart Disease CatheterizationCirculation: Cardiovascular Imaging, 2011
- Indications for Cardiac Catheterization and Intervention in Pediatric Cardiac DiseaseCirculation, 2011
- Targeted transendocardial therapeutic delivery guided by mri—x‐ray image fusionCatheterization and Cardiovascular Interventions, 2011
- Three-dimensional coronary sinus reconstruction-guided left ventricular lead implantation based on intraprocedural rotational angiography: a novel imaging modality in cardiac resynchronization device implantationEP Europace, 2011
- Use of Angiographic CT Imaging in the Cardiac Catheterization Laboratory for Congenital Heart DiseaseJACC: Cardiovascular Imaging, 2010
- Technology preview: X‐ray fused with magnetic resonance during invasive cardiovascular proceduresCatheterization and Cardiovascular Interventions, 2007
- Patient-Specific Dose and Radiation Risk Estimation in Pediatric Cardiac CatheterizationCirculation, 2005