Refraction and anterior chamber depth before and after neodymium:YAG laser treatment for posterior capsule opacification in pseudophakic eyes: A prospective study
Authors:
- Kristian NaeserKNKristian Naeser
- 1 July 1995
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 21 (4) , 457-460
Abstract
Anterior chamber depth and refraction were evaluated in 52 pseudophakic eyes before and about one month after neodymium: YAG laser capsulotomy for posterior capsule opacification. External anterior chamber depth averaged 4.06 mm before and 4.07 mm after laser treatment, a statistically insignificant change. Mean spherical equivalent refraction before laser treatment, estimated from the prescription of spectacles, was 0.30 diopters (D). Mean subjective refraction after laser treatment was 0.24 D. The difference was not significant. Mean capsulotomy opening diameter increased from 3.44 mm +/- 0.61 mm (+/- SD) immediately after the laser treatment to 3.67 mm +/- 0.61 mm one month later. The increase was statistically significant. Intraocular lens position and spherical equivalent refraction did not change after the YAG laser capsulotomy, despite a significant increase in area of the capsulotomy opening.Keywords
This publication has 13 references indexed in Scilit:
- Risk factors for posterior capsular pearling after uncomplicated extracapsular cataract extraction and plano-convex posterior chamber lens implantationJournal of Cataract & Refractive Surgery, 1993
- Displacement of bag-placed hydrogel lenses into the vitreous following neodymium:YAG laser capsulotomyJournal of Cataract & Refractive Surgery, 1990
- Retinal Detachment After Neodymium:YAG Laser Posterior CapsulotomyAmerican Journal of Ophthalmology, 1989
- Spontaneous enlargement of neodymium:YAG posterior capsulotomy in aphakic and pseudophakic patientsJournal of Cataract & Refractive Surgery, 1988
- Review of the clinical literature on the use of the Nd:YAG laser for posterior capsulotomyJournal of Cataract & Refractive Surgery, 1986
- Long-term results of Nd:YAG laser posterior capsulotomy with the Swiss laserJournal of Cataract & Refractive Surgery, 1986
- Neodymium:YAG LasersOphthalmology, 1985
- Intraocular Pressure Changes After Neodymium-YAG Laser Posterior CapsulotomyArchives of Ophthalmology (1950), 1984
- Long-term follow-up of Nd:YAG laser posterior capsulotomyAmerican Intra-Ocular Implant Society Journal, 1984
- Neodymium-Yag Laser for Posterior CapsulotomyAmerican Journal of Ophthalmology, 1983