Lagrangian Model of an Isolated DC-DC Converter With a 3-Phase Medium Frequency Transformer Accounting Magnetic Cross Saturation
Open Access
- 28 May 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 36 (2) , 880-889
Abstract
This article presents a nonlinear equivalent circuit model of an isolated dc-dc converter with a 3-phase medium frequency transformer. The model takes into account the magnetic cross saturation of the 3-phase core type magnetic circuit. The model is suitable in detailed electromagnetic transient simulations of power systems involving isolated dc-dc converters. The model is developed using the Lagrange energy method. It involves a matrix of dynamic inductances containing a nonlinear term resulting from core magnetization and a linear term resulting from leakage flux. The model parameters are determined based on a series of magnetostatic finite element method simulations. This approach is convenient when applied to high power transformers offering a limited characterization effort, or if the transformer prototype does not exist. The experimental validation performed on a novel 3-phase MFT prototype in a 100kW 1.2kV 20kHz dual active bridge converter has proved the validity of the model and model parameters. The no-load steady-state and inrush tests and the full load test show a very good fit between the simulated and experimentally measured waveforms. The comparison with a classical simplified model neglecting magnetic cross saturation shows a significant difference in the no-load inrush test.Keywords
Funding Information
- Agence Nationale de la Recherche
- Investissements d'avenir
- Gdańsk University of Technology
This publication has 43 references indexed in Scilit:
- Cascaded DC–DC Converter Connection of Photovoltaic ModulesIEEE Transactions on Power Electronics, 2004
- Accurate analytical model of winding losses in round Litz wire windingsIEEE Transactions on Magnetics, 2001
- Dynamic model of a three-phase power transformerIEEE Transactions on Power Delivery, 1993
- Analysis and design of a three-phase offline DC-DC converter with high-frequency isolationIEEE Transactions on Industry Applications, 1992
- Reduced order model for transformer transientsIEEE Transactions on Power Delivery, 1992
- Maximum likelihood estimation of transformer high frequency parameters from test dataIEEE Transactions on Power Delivery, 1991
- A three-phase soft-switched high-power-density DC/DC converter for high-power applicationsIEEE Transactions on Industry Applications, 1991
- Method of three-dimensional network solution of leakage field of three-phase transformersIEEE Transactions on Magnetics, 1990
- A Z-transform model of transformers for the study of electromagnetic transients in power systemsIEEE Transactions on Power Systems, 1990
- Transformer model for high frequenciesIEEE Transactions on Power Delivery, 1988