Sulfate Reducing Bacteria and Mycobacteria Dominate the Biofilm Communities in a Chloraminated Drinking Water Distribution System
- 22 June 2015
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 49 (14) , 8432-8440
Abstract
The quantity and composition of bacterial biofilms growing on 10 water mains from a full-scale chloraminated water distribution system were analyzed using real-time PCR targeting the 16S rRNA gene and next-generation, high-throughput Illumina sequencing. Water mains with corrosion tubercles supported the greatest amount of bacterial biomass (n = 25; geometric mean = 2.5 × 107 copies cm–2), which was significantly higher (P = 0.04) than cement-lined cast-iron mains (n = 6; geometric mean = 2.0 × 106 copies cm–2). Despite spatial variation of community composition and bacterial abundance in water main biofilms, the communities on the interior main surfaces were surprisingly similar, containing a core group of operational taxonomic units (OTUs) assigned to only 17 different genera. Bacteria from the genus Mycobacterium dominated all communities at the main wall-bulk water interface (25–78% of the community), regardless of main age, estimated water age, main material, and the presence of corrosion products. Further sequencing of the mycobacterial heat shock protein gene (hsp65) provided species-level taxonomic resolution of mycobacteria. The two dominant Mycobacteria present, M. frederiksbergense (arithmetic mean = 85.7% of hsp65 sequences) and M. aurum (arithmetic mean = 6.5% of hsp65 sequences), are generally considered to be nonpathogenic. Two opportunistic pathogens, however, were detected at low numbers: M. hemophilum (arithmetic mean = 1.5% of hsp65 sequences) and M. abscessus (arithmetic mean = 0.006% of hsp65 sequences). Sulfate-reducing bacteria from the genus Desulfovibrio, which have been implicated in microbially influenced corrosion, dominated all communities located underneath corrosion tubercules (arithmetic mean = 67.5% of the community). This research provides novel insights into the quantity and composition of biofilms in full-scale drinking water distribution systems, which is critical for assessing the risks to public health and to the water supply infrastructure.Keywords
Funding Information
- Saint Paul Regional Water Services
This publication has 60 references indexed in Scilit:
- Pyrosequence Analysis of the hsp65 Genes of Nontuberculous Mycobacterium Communities in Unchlorinated Drinking Water in the NetherlandsApplied and Environmental Microbiology, 2013
- Molecular Survey of the Occurrence of Legionella spp., Mycobacterium spp., Pseudomonas aeruginosa, and Amoeba Hosts in Two Chloraminated Drinking Water Distribution SystemsApplied and Environmental Microbiology, 2012
- Metagenomic Analyses of Drinking Water Receiving Different Disinfection TreatmentsApplied and Environmental Microbiology, 2012
- Biofilms in drinking water and their role as reservoir for pathogensInternational Journal of Hygiene and Environmental Health, 2011
- UCHIME improves sensitivity and speed of chimera detectionBioinformatics, 2011
- Generation of Multimillion-Sequence 16S rRNA Gene Libraries from Complex Microbial Communities by Assembling Paired-End Illumina ReadsApplied and Environmental Microbiology, 2011
- Introducing mothur: Open-Source, Platform-Independent, Community-Supported Software for Describing and Comparing Microbial CommunitiesApplied and Environmental Microbiology, 2009
- The Ribosomal Database Project: improved alignments and new tools for rRNA analysisNucleic Acids Research, 2008
- Sequencing of hsp65 Gene for Identification of Mycobacterium Species Isolated from Environmental and Clinical Sources in Rio de Janeiro, BrazilJournal of Clinical Microbiology, 2008
- UniFrac: a New Phylogenetic Method for Comparing Microbial CommunitiesApplied and Environmental Microbiology, 2005