Mapping myocardial perfusion with an intravascular MR contrast agent: Robustness of deconvolution methods at various blood flows
Open Access
- 27 June 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (1) , 166-179
Abstract
Evaluation of quantitative parameters such as regional myocardial blood flow (rMBF), blood volume (rMBV), and mean transit time (rMTT) by MRI is gaining acceptance for clinical applications, but still lacks robust postprocessing methods for map generation. Moreover, robustness should be preserved over the full range of myocardial flows and volumes. Using experimental data from an isolated pig heart preparation, synthetic MR kinetics were generated and four deconvolution approaches were evaluated. These methods were then applied to the first‐pass T1 images of the isolated pig heart using an intravascular contrast agent and rMBF, rMBV and rMTT maps were generated. In both synthetic and experimental data, the fit between calculated and original data reached equally good results with the four techniques. rMBV was the only parameter estimated correctly in numerical experiments. Moreover, using the algebraic method ARMA, abnormal regions were well delineated on rMBV maps. At high flows, rMBF was underestimated at the experimental noise level. Finally, rMTT maps appeared noisy and highly unreliable, especially at high flows. In conclusion, over the myocardial flow range, i.e., 0–400 ml/min/100g, rMBF identification was biased in presence of noise, whereas rMBV was correctly identified. Thus, rMBV mapping could be a fast and robust way to detect abnormal myocardial regions. Magn Reson Med 48:166–179, 2002.Keywords
This publication has 38 references indexed in Scilit:
- Kinetic characterization of CMD-A2-Gd-DOTA as an intravascular contrast agent for myocardial perfusion measurement with MRIMagnetic Resonance in Medicine, 2000
- Quantification of myocardial perfusion with FAST sequence and Gd bolus in patients with normal cardiac functionJournal of Magnetic Resonance Imaging, 1999
- Capillary transfer constant of Gd‐DTPA in the myocardium at rest and during vasodilation assessed by MRIMagnetic Resonance in Medicine, 1998
- Cerebral Blood Flow Measurements by Magnetic Resonance Imaging Bolus Tracking: Comparison with [15O]H2O Positron Emission Tomography in HumansJournal of Cerebral Blood Flow & Metabolism, 1998
- Absolute Cerebral Blood Flow and Blood Volume Measured by Magnetic Resonance Imaging Bolus Tracking: Comparison with Positron Emission Tomography ValuesJournal of Cerebral Blood Flow & Metabolism, 1998
- Normal myocardial perfwsion assessed with multishot echo‐planar imagingMagnetic Resonance in Medicine, 1997
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- An unbiased parametric imaging algorithm for nonuniformly sampled biomedical system parameter estimationIEEE Transactions on Medical Imaging, 1996
- Measurement of the extraction efficiency and distribution volume for Gd‐DTPA in normal and diseased canine myocardiumMagnetic Resonance in Medicine, 1993
- Pitfalls in MR measurement of tissue blood flow with intravascular tracers: Which mean transit time?Magnetic Resonance in Medicine, 1993