Smartphone-Based Dual-Channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-Phenoxybenzoic Acid
- 30 September 2021
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (40) , 13658-13666
Abstract
Currently, gas chromatography–mass spectrometry (GC–MS) and liquid chromatography–MS (LC–MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC–MS and LC–MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultrahigh fluorescent brightness were synthesized and used as a signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCD-conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in the sample. The red fluorescence on the test line was then recorded using a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 to 100 ng/mL and from 0.1 to 100 ng/mL, respectively, and the limits of detection were calculated to be ∼0.35 ng/mL for cypermethrin and ∼0.04 ng/mL for 3-PBA. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.Keywords
Funding Information
- National Institute of Environmental Health Sciences (ES030443-01, P42ES004699)
- National Institute for Occupational Safety and Health (R01OH011023-01A1)
This publication has 46 references indexed in Scilit:
- Isolation of Alpaca Anti-Hapten Heavy Chain Single Domain Antibodies for Development of Sensitive ImmunoassayAnalytical Chemistry, 2011
- Immunoassays and Biosensors for Monitoring Environmental and Human Exposure to Pyrethroid InsecticidesJournal of Agricultural and Food Chemistry, 2010
- Measurement of pyrethroid, organophosphorus, and carbamate insecticides in human plasma using isotope dilution gas chromatography–high resolution mass spectrometryJournal of Chromatography B, 2010
- Validity of the rapid strip assay test for detecting HBsAg in patients admitted to hospital in UgandaJournal of Medical Virology, 2010
- Quantum Dots as Reporters in Multiplexed Immunoassays for Biomarkers of Exposure to AgrochemicalsAnalytical Letters, 2007
- Magnetic enhancement of iron oxide nanoparticles encapsulated with poly(d,l-latide-co-glycolide)Colloids and Surfaces A: Physicochemical and Engineering Aspects, 2005
- Hapten and Antibody Production for a Sensitive Immunoassay Determining a Human Urinary Metabolite of the Pyrethroid Insecticide PermethrinJournal of Agricultural and Food Chemistry, 2004
- A Sensitive Class Specific Immunoassay for the Detection of Pyrethroid Metabolites in Human UrineChemical Research in Toxicology, 2004
- Homogeneous fluoroimmunoassay of a pyrethroid metabolite in urineAnalytica Chimica Acta, 2001
- Development of an Enzyme-Linked Immunosorbent Assay for the Detection of the Pyrethroid Insecticide FenpropathrinJournal of Agricultural and Food Chemistry, 1998