Effects of gripping volume in the mechanical strengths of orthodontic mini‐implant
Open Access
- 25 April 2017
- journal article
- Published by Wiley in The Kaohsiung Journal of Medical Sciences
- Vol. 33 (11) , 578-583
Abstract
The objective of study was to investigate the correlation between the mechanical strengths [insertion torque (IT); resonance frequency (RF); and horizontal pullout strength (HPS)] and gripping volume (GV) of mini-implants. Thirty mini-implants of three types (Type A: 2 mm × 10 mm, cylindrical, titanium alloy; Type B: 2 mm × 10 mm, tapered, stainless steel; and Type C: 2 mm × 11 mm, cylindrical, titanium alloy) were inserted 7 mm into artificial bones. One-way analysis of variance and Spearman's test were applied to assess intergroup comparisons and intragroup correlations. The null hypothesis was that no statistically significant correlations exist between the GV and mechanical strengths (IT, RF, and HPS). In the IT test, Type C (14.2 Ncm) had significantly (p=0.016) greater values than did Type A (12.4 Ncm). In the RF analysis, no significant difference was observed among the three types of mini-implants. In the HPS test, Type C (388.9 Ncm) was significantly larger than both Type B (294.5 Ncm) and Type A (286 Ncm). In the GV measurement, Type C (14.4 mm3) was significantly larger than Type B (11.4 mm3) and Type A (9.2 mm3). Type A and Type B exhibited no significant correlations among the tests. Therefore, the null hypothesis was accepted. Although no significant correlation was noted between the GV and mechanical strengths (IT, RF, and HPS), we observed a trend that the mechanical strengths (IT, RF, and HPS) of the mini-implants corresponded to the order and values of GV (Type C > Type B > Type A).Keywords
This publication has 15 references indexed in Scilit:
- Influence of bone architecture on the primary stability of different mini-implant designsAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2015
- Implants for Orthodontic AnchorageImplant Dentistry, 2014
- Insertion torque, pull-out strength and cortical bone thickness in contact with orthodontic mini-implants at different insertion anglesEuropean Journal of Orthodontics, 2013
- Insertion torque and success of orthodontic mini-implants: A systematic reviewAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2012
- Horizontal Pull-Out Strength of Orthodontic Infrazygomatic Mini-Implant: An In Vitro StudyImplant Dentistry, 2011
- In vitro evaluation of insertion and removal torques of orthodontic mini-implantsInternational Journal of Oral and Maxillofacial Surgery, 2011
- A torque removal study on the primary stability of orthodontic titanium screw mini-implants in the cortical bone of dog femursInternational Journal of Oral and Maxillofacial Surgery, 2008
- Relevance of resonance frequency analysis to evaluate dental implant stability: simulation and histomorphometrical animal experimentsClinical Oral Implants Research, 2007
- The application of mini-implants for orthodontic anchorageInternational Journal of Oral and Maxillofacial Surgery, 2006
- The relationship between attachment level loss and alveolar bone lossJournal of Clinical Periodontology, 1984