Average saturation efficiency filter ASEF‐CEST MRI of stroke rodents
- 27 October 2022
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 89 (2) , 565-576
Abstract
Purpose: The average saturation efficiency filter (ASEF) is a novel method of improving the specificity of CEST; however, there is a mismatch between the magnetization transfer (MT) effect under high‐duty cycle and low‐duty cycle pulse trains. We explore measures of mitigation and the sensitivity and potential of ASEF imaging in phantoms and stroke rats.Methods: Simulation and nicotinamide phantoms in denatured protein were used to investigate the effect of different average saturation powers and MT pool parameters on matching coefficients used for correction as well as the ASEF ratio signal and baseline. Then, in vivo studies were performed in stroke rodents to further investigate the sensitivity and fidelity of ASEF ratio spectra.Results: Simulation and studies of nicotinamide phantoms show that the matching coefficient needed to correct the baseline MT mismatch is strongly dependent on the average saturation power. In vivo studies in stroke rodents show that the matching coefficient required to correct the baseline MT mismatch is different for normal versus ischemic tissue. Thus, a baseline correction was performed to further suppress the residue MT mismatch. After correction of the mismatch, ASEF ratio achieved comparable contrast at 3.6 ppm between normal and ischemic tissue when compared to the apparent amide proton transfer (APT*) approach. Moreover, contrasts for 2.0 and 2.6 ppm were also ascertainable from the same spectra.Conclusion: ASEF can improve the CEST signal specificity of slow exchange labile protons such as amide and guanidyl, with small loss to sensitivity. It has strong potential in the CEST imaging of various diseases.Keywords
Funding Information
- National Institutes of Health (NS100703)
This publication has 51 references indexed in Scilit:
- Imaging the pH evolution of an acute kidney injury model by means of iopamidol, a MRI-CEST pH-responsive contrast agentMagnetic Resonance in Medicine, 2012
- Magnetic resonance imaging of the Amine–Proton EXchange (APEX) dependent contrastNeuroImage, 2012
- Quantitative separation of CEST effect from magnetization transfer and spillover effects by Lorentzian-line-fit analysis of z-spectraJournal of Magnetic Resonance, 2011
- Simulation and optimization of pulsed radio frequency irradiation scheme for chemical exchange saturation transfer (CEST) MRI—demonstration of pH‐weighted pulsed‐amide proton CEST MRI in an animal model of acute cerebral ischemiaMagnetic Resonance in Medicine, 2011
- Saturation power dependence of amide proton transfer image contrasts in human brain tumors and strokes at 3 TMagnetic Resonance in Medicine, 2011
- Association between pH-Weighted Endogenous Amide Proton Chemical Exchange Saturation Transfer MRI and Tissue Lactic Acidosis during Acute Ischemic StrokeJournal of Cerebral Blood Flow & Metabolism, 2011
- In vivo mapping of brain myo-inositolNeuroImage, 2011
- Differentiation between glioma and radiation necrosis using molecular magnetic resonance imaging of endogenous proteins and peptidesNature Medicine, 2010
- Spin-locking versus chemical exchange saturation transfer MRI for investigating chemical exchange process between water and labile metabolite protonsMagnetic Resonance in Medicine, 2010
- Water saturation shift referencing (WASSR) for chemical exchange saturation transfer (CEST) experimentsMagnetic Resonance in Medicine, 2009