Clinical implementation of kVCT-guided tomotherapy with ClearRT
Authors:
- 4 August 2022
- journal article
- research article
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 45 (3) , 915-924
Abstract
A helical fan-beam kilovoltage computed tomography (kVCT) was recently introduced into Tomotherapy units. This study aims to share the initial experience of kVCT in clinical workflow, compare its performance with that of the existing megavoltage computed tomography (MVCT), and explore its potential in adaptive planning. We retrospectively enrolled 23 patients who underwent both MVCT and kVCT scans. The clinical performance data regarding image acquisition time, nominal dose length product (DLP), registration time and registration corrections were extracted and compared. Image quality was scored by six experienced radiation therapists and quantified based on phantom measurements. CT number stability and the implementation of adaptive radiotherapy were dosimetrically evaluated by performing the dose recalculation on kVCT. Compared to MVCT, kVCT significantly reduced DLP (except the highest kVp protocol), image acquisition and registration time. KVCT obtained higher scores than MVCT on all criteria except artifacts. Phantom measurements also revealed a better image performance characterization of kVCT except for image uniformity. The CT number variation could lead to a dose difference of 0.5% for D95% of target and Dmean of organ-at-risk. For the treatment planning with kVCT, a systematic dose difference (> 1%) in PTV dose metrics was observed at regions with large longitudinal density discontinuities compared to the reference plans. The new kVCT imaging provides enhanced soft-tissue visualization. The improved efficiency with kVCT-guided treatment will allow more patients to be treated each day. In most cases, the dose calculation accuracy of kVCT images is acceptable except for regions with severe artifacts.Keywords
All Related Versions
This publication has 12 references indexed in Scilit:
- Artefacts in CBCT: a reviewDentomaxillofacial Radiology, 2011
- Megavoltage CT images of helical tomotherapy unit for radiation treatment simulation: impact on feasibility of treatment planning in a prostate cancer patient with bilateral femoral prostheses2011
- Utility of Megavoltage Fan-Beam CT for Treatment Planning in a Head-And-Neck Cancer Patient with Extensive Dental Fillings Undergoing Helical TomotherapyMedical Dosimetry, 2010
- QA for helical tomotherapy: Report of the AAPM Task Group 148a)Medical Physics, 2010
- Delineation of moving targets with slow MVCT scans: implications for adaptive non-gated lung tomotherapyPhysics in Medicine & Biology, 2007
- The use of megavoltage cone-beam CT to complement CT for target definition in pelvic radiotherapy in the presence of hip replacementBritish Journal of Radiology, 2006
- Performance characterization of megavoltage computed tomography imaging on a helical tomotherapy unitMedical Physics, 2005
- Helical Tomotherapy: An Innovative Technology and Approach to Radiation TherapyTechnology in Cancer Research & Treatment, 2002
- Tolerance levels for quality assurance of electron density values generated from CT in radiotherapy treatment planningPhysics in Medicine & Biology, 2002
- TomotherapySeminars in Radiation Oncology, 1999