The dynamic behaviour of the roof interventions in the Basilica San Francesco in Assisi
Authors:
- Vincenzo ArcidiaconoVAVincenzo Arcidiacono
- Emidio PiermariniEPEmidio Piermarini
- Gian Paolo CimellaroGCGian Paolo Cimellaro
- John OschendorfJOJohn Oschendorf
- 1 January 2015
- conference paper
- Published by International Association for Bridge and Structural Engineering (IABSE)
- Vol. 104, 208-209
Abstract
During the 1997 Umbria-Marche earthquake, two of the vaults of the Basilica of San Francesco in Assisi collapsed as a result of two earthquakes with 5.6 and 5.8 magnitudes. The structure had endured stronger earthquakes for centuries before these events, and there are likely many reasons for the 1997 collapse, such as damages cumulated from previous earthquakes or the retrofitting made to the structure over its lifetime. A full description and history of the different retrofit interventions of the Basilica are presented. In particular, the Basilica's roof has been subjected to three major restorations in its life. Besides, this study considers the effects of the different roof interventions on the global dynamic behavior of the structure. A simple analytical model is employed to show trends in the structure's seismic response to the 2nd shock of the 1997 earthquake given the changes in stiffness and mass of the roof over the centuries. The results of the analytical model suggest that the roof interventions have had the effect of decreasing the structure's fundamental period, and therefore, attracting more seismic loads to the façade and the transept. These were overloaded, leading to a probable nonlinear behavior that might explain the collapse of the two Gothic vaults.Keywords
This publication has 10 references indexed in Scilit:
- Reply to “Discussion 2 on ‘Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake’ by G.P. Cimellaro, A.M. Reinhorn and A.De Stefano” by Enzo CartapatiEarthquake Engineering and Engineering Vibration, 2012
- Reply to “Discussion 1 on ‘Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquake’ by G.P. Cimellaro, A.M. Reinhorn and A.De Stefano” by Vincenzo CiampiEarthquake Engineering and Engineering Vibration, 2012
- Damage assessment of churches after L’Aquila earthquake (2009)Bulletin of Earthquake Engineering, 2011
- Introspection on improper seismic retrofit of Basilica Santa Maria di Collemaggio after 2009 Italian earthquakeEarthquake Engineering and Engineering Vibration, 2011
- Cultural Heritage Buildings and the Abruzzo Earthquake: Performance and Post-Earthquake ActionsAdvanced Materials Research, 2010
- The Case Study of Santa Maria Paganica Church Damaged by 2009 L’Aquila EarthquakeAdvanced Materials Research, 2010
- Architecture of Italy2008
- Seismic Vulnerability of Ancient Churches: I. Damage Assessment and Emergency PlanningEarthquake Spectra, 2004
- Modelling and analysis of a basilica under earthquake loadingJournal of Cultural Heritage, 2003
- Strengthening the Basilica of St Francis of Assisi after the September 1997 EarthquakeStructural Engineering International, 2001