Desorption ionization using through‐hole alumina membrane offers higher reproducibility than 2,5‐dihydroxybenzoic acid, a widely used matrix in Fourier transform ion cyclotron resonance mass spectrometry imaging analysis
Open Access
- 2 March 2021
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 35 (10) , e9076
Abstract
Rationale: DIUTHAME (desorption ionization using through‐hole alumina membrane), a recently developed matrix‐free ionization‐assisting substrate, was examined for reproducibility in terms of mass accuracy and intensity using standard lipid and mouse brain sections. The impregnation property of DIUTHAME significantly improved the reproducibility of mass accuracy and intensity compared with 2,5‐dihydroxybenzoic acid (DHB). Methods: Frozen tissue sections were mounted on indium tin oxide‐coated glass slides. DIUTHAME and DHB were applied to individual sections. Subsequently, a solution of a phosphatidylcholine standard, PC(18:2/18:2), was poured onto the DIUTHAME and matrix. Finally, the samples were subjected to laser desorption ionization coupled with Fourier transform ion cyclotron resonance mass spectrometry. The reproducibility was tested by calculating the mean ± standard deviation values of mass errors and intensities of individual ion species. Results: Analysis of the PC(18:2/18:2) standard showed significantly ( p < 0.01) lower mass error for DIUTHAME‐MS than for MALDI‐MS. Endogenous PC(36:4) analysis in mouse brain section also showed significantly ( p < 0.05) lower mass errors for DIUTHAME‐MS. Furthermore, we investigated the mass error of some abundant lipid ions in brain sections and observed similar results. DIUTHAME‐MS displayed lower signal intensity in standard PC analysis. Interestingly, it offered higher signal intensities for all the endogenous lipid ions. Lower fluctuations of both mass accuracies and signal intensities were observed in DIUTHAME‐MS. Conclusions: Our results demonstrated that DIUTHAME‐MS offers higher reproducibility for mass accuracies and intensities than MALDI‐MS in both standard lipid and mouse brain tissue analyses. It can potentially be used instead of conventional MALDI‐MS and mass spectrometry imaging analyses to achieve highly reproducible data for mass accuracy and intensity.Keywords
Funding Information
- Japan Agency for Medical Research and Development (JP20gm0910004)
This publication has 69 references indexed in Scilit:
- Region-specific effects of Scrapper on the abundance of glutamate and gamma-aminobutyric acid in the mouse brainScientific Reports, 2020
- Higher Accumulation of Docosahexaenoic Acid in the Vermilion of the Human Lip than in the SkinInternational Journal of Molecular Sciences, 2020
- Green Nut Oil or DHA Supplementation Restored Decreased Distribution Levels of DHA Containing Phosphatidylcholines in the Brain of a Mouse Model of DementiaMetabolites, 2020
- Distribution of Antisense Oligonucleotides in Rat Eyeballs Using MALDI Imaging Mass SpectrometryMass Spectrometry, 2018
- Secondary Ion Mass Spectrometry Imaging of Tissues, Cells, and Microbial SystemsMicroscopy Today, 2016
- MALDI Imaging Mass Spectrometry—A Mini Review of Methods and Recent DevelopmentsMass Spectrometry, 2013
- MALDI Imaging of Lipid Biochemistry in Tissues by Mass SpectrometryChemical Reviews, 2011
- MALDI-FTICR Imaging Mass Spectrometry of Drugs and Metabolites in TissueAnalytical Chemistry, 2008
- Tissue Imaging at Atmospheric Pressure Using Desorption Electrospray Ionization (DESI) Mass SpectrometryAngewandte Chemie International Edition, 2006
- Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MSAnalytical Chemistry, 1997