Human Observer Sensitivity to Temporal Noise During B-Mode Ultrasound Scanning: Characterization and Imaging Implications
- 18 March 2024
- journal article
- research article
- Published by SAGE Publications in Ultrasonic Imaging
- Vol. 46 (3) , 151-163
Abstract
This work measures temporal signal-to-noise ratio (SNR) thresholds that indicate when random noise during ultrasound scanning becomes imperceptible to expert human observers. Visible noise compromises image quality and can potentially lead to non-diagnostic scans. Noise can arise from both stable acoustic sources (clutter) or randomly varying electronic sources (temporal noise). Extensive engineering effort has focused on decreasing noise in both of these categories. In this work, an observer study with five practicing sonographers was performed to assess sonographer sensitivity to temporal noise in ultrasound cine clips. Understanding the conditions where temporal noise is no longer visible during ultrasound imaging can inform engineering efforts seeking to minimize the impact this noise has on image quality. The sonographers were presented with paired temporal noise-free and noise-added simulated speckle cine clips and asked to select the noise-added clips. The degree of motion in the imaging target was found to have a significant effect on the SNR levels where noise was perceived, while changing imaging frequency had little impact. At realistic in vivo motion levels, temporal noise was not perceived in cine clips at and above 28 dB SNR. In a case study presented here, the potential of adaptive intensity adjustment based on this noise perception threshold is validated in a fetal imaging scenario. This study demonstrates how noise perception thresholds can be applied to help design or tune ultrasound systems for different imaging tasks and noise conditions.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R01-EB017711)
- National Institute of Biomedical Imaging and Bioengineering (R01-EB026574)
- Division of Graduate Education (DGE 2139754)
This publication has 25 references indexed in Scilit:
- An Automated ALARA Method for UltrasoundJournal of Ultrasound in Medicine, 2020
- Ultrasound Image Optimization (“Knobology”): B-ModeUltrasound International Open, 2020
- Safety Indices of Ultrasound: Adherence to Recommendations and Awareness During Routine Obstetric Ultrasound ScanningUltraschall in der Medizin - European Journal of Ultrasound, 2020
- Clinical Utility of Fetal Short-Lag Spatial Coherence ImagingUltrasound in Medicine & Biology, 2018
- Quantifying Image Quality Improvement Using Elevated Acoustic Output in B-Mode Harmonic ImagingUltrasound in Medicine & Biology, 2017
- Ultrasound image enhancement: A reviewBiomedical Signal Processing and Control, 2012
- Diffeomorphic demons: Efficient non-parametric image registrationNeuroImage, 2009
- Advances in UltrasoundClinical Radiology, 2002
- Image matching as a diffusion process: an analogy with Maxwell's demonsMedical Image Analysis, 1998
- Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducersIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1992