New Criteria Reduce Inter-Observer Variability in Chronic Cerebrospinal Venous Insufficiency: A Case Control Study
Authors:
- Monza Polyclinic Director Of Phlebolymphologic Diseases CentreMCMonza Polyclinic Director Of Phlebolymphologic Diseases Centre
- Massimiliano FarinaMFMassimiliano Farina
- Villa Cimarosa Medical Centre Angiology UnitVUVilla Cimarosa Medical Centre Angiology Unit
Open Access
- 28 December 2017
- journal article
- Published by Openventio Publishers in Neuro
- Vol. 4 (1) , 1-10
Abstract
Background: The pathophysiological mechanism defined “chronic cerebrospinal venous insufficiency” (CCSVI) diagnosed using Zamboni criteria has raised a heated debate about possible correlations with several neurological disorders, but also on subjectivity of these ultrasonographic criteria used for its diagnosis. Although in 2011 new criteria have been introduced to reduce the high inter-observer variability only two studies were conducted according to the new investigation protocol. Therefore, we wanted to verify the impact of the revised protocol and its ability to meet the demand for reduction of the high heterogeneity in inter-observer agreement. Patients and Methods: Between June 2010 and June 2014, 1020 subjects (693 MS patients and 327 HCs) were prospectively screened for CCSVI by two investigators, blinded regarding the observed subject. After exclusion of discordant cases between the two examiners, 630 patients with clinically defined MS and 10 patients with CIS (clinically isolated syndrome) were matched by gender (male 38.7%, male/female 248/392) and age (mean age 44.0 years, range 18.5-77.0 years) with 315 HCs (male 43.2%, male/female 136/179-mean age 46.5 years, range 19.8-79.9 years).Results: The prevalence of CCSVI in MS subjects before the introduction of the new ECD criteria (94.3%) was observed to be significantly reduced (83.4%) after their introduction (p<0.001). In MS patients, the strength of inter-observer agreement changed from moderate (k=0.532) to good (k=0.761) before/after the revision. B-mode analysis detected only 65.7% of valvular defects. Its diagnostic accuracy was 88.6% (95% CI: 84.0%-93.2%), with a sensitivity of 83.5% (95% CI: 75.2%-89.9%), a specificity of 96.0% (95% CI: 88.8%-99.2%), a positive predictive value of 96.8% (95% CI: 91.0%-99.3%) and a negative predictive value of 80.0% (95% CI: 70.3%-87.7%).Conclusions: The new ECD criteria introduced by the revised protocol ensure, at this time, a substantial reduction of the inter-observer variability. Under this perspective, M-mode analysis is essential for its ability to identify the valvular abnormalities frequently not detectable by Bmode analysis.Keywords
This publication has 47 references indexed in Scilit:
- “Liberation treatment” for chronic cerebrospinal venous insufficiency in multiple sclerosis: the truth will set you freeBrain and Behavior, 2014
- Doppler Ultrasound Examination of Multiple Sclerosis Patients and Control Participants: Inter-observer Agreement and Association with DiseaseEuropean Journal of Vascular and Endovascular Surgery, 2013
- Chronic cerebrospinal venous insufficiency in multiple sclerosis: A sonographer-blinded case-control studyClinical Neurology and Neurosurgery, 2013
- Chronic cerebrospinal venous insufficiencyAnnals of Neurology, 2012
- CCSVI and MS: a statement from the European Society of neurosonology and cerebral hemodynamicsJournal of Neurology, 2012
- Diagnostic criteria for multiple sclerosis: 2010 Revisions to the McDonald criteriaAnnals of Neurology, 2011
- Cardiovascular and Interventional Radiological Society of Europe Commentary on the Treatment of Chronic Cerebrospinal Venous InsufficiencyCardioVascular and Interventional Radiology, 2010
- Interventional Endovascular Management of Chronic Cerebrospinal Venous Insufficiency in Patients with Multiple Sclerosis: A Position Statement by the Society of Interventional Radiology, Endorsed by the Canadian Interventional Radiology AssociationJournal of Vascular and Interventional Radiology, 2010
- Chronic cerebrospinal venous insufficiency and multiple sclerosisAnnals of Neurology, 2010
- Optimization of cardiac preload during laparoscopic donor nephrectomy: A preliminary study of central venous pressure versus esophageal doppler monitoringSurgical Endoscopy, 2004