Early Results With the New Active Bone‐Conduction Hearing Implant: A Systematic Review and Meta‐Analysis
Open Access
- 26 March 2024
- journal article
- review article
- Published by Wiley in Otolaryngology–Head and Neck Surgery
- Vol. 170 (6) , 1630-1647
Abstract
Objective: The bone conduction implant (BCI) 602 is a new transcutaneous BCI with smaller dimensions. However, limited patient numbers restrict the statistical power and generalizability of the current studies. The present systematic review and meta‐analysis summarize early audiological and medical outcomes of adult and pediatric patients implanted with the BCI 602 due to mixed or conductive hearing loss.Data Source: Following the Preferred Reporting items for Systematic Reviews and Meta‐analyses guidelines, 108 studies were reviewed, and 6 (5.6%) were included in the meta‐analysis.Review Method: The data on study and patient characteristics, surgical outcomes, and audiological test results were extracted from each article. Meta‐analysis employed the fixed‐effect and random‐effects models to analyze the mean differences (MDs) between pre‐ and postoperative performances.Results: In total, 116 patients were evaluated, including 64 (55%) adult and 52 (45%) pediatric patients. No intraoperative adverse events were reported, while postoperative complications were reported in 2 (3.1%) adult and 2 (3.8%) pediatric patients. Studies consistently showed significant improvements in audiological outcomes, quality of life, and sound localization in the aided condition. In the meta‐analysis, we observed a significant difference in the unaided compared to the aided condition in sound field thresholds (n = 112; MD, −27.05 dB; P < 0.01), signal‐to‐noise ratio (n = 96; MD, −6.35 dB; P < 0.01), and word recognition scores (n = 96; MD, 68.89%; P < 0.01).Conclusion: The implantation of the BCI 602 was associated with minimal surgical complications and excellent audiological outcomes for both the pediatric and the adult cohort. Therefore, our analysis indicates a high level of safety and reliability. Further research should focus on direct comparisons with other BCIs and long‐term functional outcomes.Keywords
This publication has 51 references indexed in Scilit:
- Systematic Review and Meta‐Analysis of a New Active Transcutaneous Bone Conduction ImplantThe Laryngoscope, 2023
- Experience With the New Active Transcutaneous Bone‐Conduction Implant With Smaller DimensionsOtolaryngology–Head and Neck Surgery, 2023
- Two Bonebridge bone conduction hearing implant generations: audiological benefit and quality of hearing in childrenEuropean Archives of Oto-Rhino-Laryngology, 2021
- Clinical and functional results after implantation of the bonebridge, a semi-implantable, active transcutaneous bone conduction device, in children and adultsEuropean Archives of Oto-Rhino-Laryngology, 2021
- Cochlear Implantation in Children With Single-Sided DeafnessJAMA Otolaryngology–Head & Neck Surgery, 2021
- Implantation of a new active bone conduction hearing device with optimized geometryHNO, 2020
- Guideline “Implantable hearing aids”—short versionHNO, 2018
- Improvement of speech perception in quiet and in noise without decreasing localization abilities with the bone conduction device BonebridgeEuropean Archives of Oto-Rhino-Laryngology, 2016
- Postoperative pain in patients undergoing a transcutaneous active bone conduction implant (Bonebridge)European Archives of Oto-Rhino-Laryngology, 2016
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002