Detection of Nitrogen Dioxide by Cavity Attenuated Phase Shift Spectroscopy
Authors:
- 20 November 2004
- journal article
- editorial
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (2) , 724-728
Abstract
We present initial results obtained from an optical absorption sensor for the monitoring of ambient atmospheric nitrogen dioxide concentrations (0−200 ppb). This sensor utilizes cavity attenuated phase shift spectroscopy, a technology related to cavity ringdown spectroscopy. A modulated broadband incoherent light source (a 430-nm LED) is coupled to an optically resonant cavity formed by two high-reflectivity mirrors. The presence of NO2 in the cell causes a phase shift in the signal received by a photodetector that is proportional to the NO2 concentration. The sensor, which employed a 0.5-m cell, was shown to have a sensitivity of 0.3 ppb in the photon (shot) noise limit. Improvements in the optical coupling of the LED to the resonant cavity would allow the sensor to reach this limit with integration times of 10 s or less (corresponding to a noise equivalent absorption coefficient of -8 cm-1 Hz-1/2). Over a 2-day-long period of ambient atmospheric monitoring, a comparison of the sensor with an extremely accurate and precise tunable diode laser-based absorption spectrometer showed that the CAPS-based instrument was able to reliably and quantitatively measure both large and small fluctuations in the ambient nitrogen dioxide concentration.Keywords
This publication has 17 references indexed in Scilit:
- Absorption Spectroscopy in High-Finesse Cavities for Atmospheric StudiesChemical Reviews, 2003
- 410-nm diode laser cavity ring-down spectroscopy for trace detection of NO2Chemical Physics Letters, 2003
- Direct measurement of NO2 in the marine atmosphere by laser-induced fluorescence techniqueAtmospheric Environment, 2001
- Collection of Leakage Statistics in the Natural Gas System by Tracer MethodsEnvironmental Science & Technology, 1997
- Cavity Ringdown Laser Absorption Spectroscopy: History, Development, and Application to Pulsed Molecular BeamsChemical Reviews, 1997
- Phase shift cavity ring down absorption spectroscopyChemical Physics Letters, 1996
- Ultrasensitive, visible tunable diode laser detection of NO_2Applied Optics, 1996
- Temperature dependent ultraviolet‐visible absorption cross sections of N2O and N2O4: Low‐temperature measurements of the equilibrium constant for 2NO2 ⇌ N2O4Journal of Geophysical Research: Atmospheres, 1994
- Response of commercial chemiluminescent nitric oxide-nitrogen dioxide analyzers to other nitrogen-containing compoundsEnvironmental Science & Technology, 1974
- Electrophoretic desalting of acid hydrolysates for the isolation of amino acidsAnalytical Chemistry, 1973