Clinical Outcomes of Pulsed Field Vs. Thermal Ablation for Paroxysmal Atrial Fibrillation: Systematic Review and Meta‐Analysis of Randomized Evidence
Authors:
- Asad Ali Ahmed CheemaACAsad Ali Ahmed Cheema
- Reshail AsifRAReshail Asif
- Unsa ArifUAUnsa Arif
- Manahil MalikMMManahil Malik
- Sarah MisbahSMSarah Misbah
- Eraj NadeemENEraj Nadeem
- Muhammad Iftikhar AlamMAMuhammad Iftikhar Alam
- Deep BirjaniDBDeep Birjani
- Syed Umair AhmedSASyed Umair Ahmed
- Fnu HamnaFHFnu Hamna
- Hadia Haseeb AhmadHAHadia Haseeb Ahmad
- Fizza SajidFSFizza Sajid
Open Access
- 20 August 2026
- journal article
- review article
- Published by Wiley in Journal of Arrhythmia
- Vol. 42 (4) , e70446
Abstract
Aims: Pulsed field ablation (PFA) is a non‐thermal alternative to conventional thermal ablation for paroxysmal atrial fibrillation (AF). We conducted an updated systematic review and meta‐analysis of randomized evidence comparing efficacy, safety, and procedural outcomes. Methods: PubMed/MEDLINE and the Cochrane Central Register of Controlled Trials were searched from inception through March 2026 for randomized controlled trials (RCTs) comparing PFA with thermal ablation in adults undergoing first catheter ablation for paroxysmal AF. Risk ratios (RRs) or mean differences (MDs) with 95% confidence intervals (CIs) were pooled using random‐effects models. Results: Four RCTs enrolling 1 393 patients were included. PFA showed no statistically detectable difference in 12‐month treatment success (RR, 1.04; 95% CI, 0.97 to 1.12; I 2 = 7%), recurrent atrial arrhythmias (RR, 1.00; 95% CI, 0.77 to 1.29; I 2 = 42%), or composite serious adverse events (RR, 0.71; 95% CI, 0.32 to 1.57; I 2 = 7%). PFA shortened procedure time (MD, −22.42 min; 95% CI, −33.44 to −11.39; I 2 = 91%) and LA dwell time (MD, −25.73 min; 95% CI, −34.66 to −16.79; I 2 = 92%), but increased fluoroscopy time (MD, 7.34 min; 95% CI, 0.39 to 14.30; I 2 = 98%). Conclusions: Across the included trial configurations, 12‐month efficacy estimates did not differ detectably. Sparse safety events and wide confidence intervals precluded equivalence claims. Pooled procedure and LA dwell times favored PFA, but platform, comparator, and workflow heterogeneity limit generalizability. Procedural findings are exploratory and should not be interpreted as direct energy‐specific effects.Keywords
This publication has 28 references indexed in Scilit:
- Pulsed Field Ablation Using a Novel Biphasic Catheter vs Thermal Ablation for Paroxysmal Atrial FibrillationJACC, 2025
- Pulsed‐Field Ablation Versus Radiofrequency Ablation for Paroxysmal Atrial Fibrillation: A Systematic Review and Meta‐AnalysisJournal of Arrhythmia, 2025
- Efficacy and safety of pulsed‐field versus conventional thermal ablation for atrial fibrillation: A systematic review and meta‐analysisJournal of Arrhythmia, 2024
- Safety of pulsed field ablation in more than 17,000 patients with atrial fibrillation in the MANIFEST-17K studyNature Medicine, 2024
- Pulsed-field ablation versus thermal ablation for atrial fibrillation: A meta-analysisHeart Rhythm, 2024
- 2023 ACC/AHA/ACCP/HRS Guideline for the Diagnosis and Management of Atrial FibrillationJACC, 2023
- Cochrane Handbook for Systematic Reviews of Interventions2019
- GRADE guidelines: 13. Preparing Summary of Findings tables and evidence profiles—continuous outcomesJournal of Clinical Epidemiology, 2013
- GRADE guidelines: 1. Introduction—GRADE evidence profiles and summary of findings tablesJournal of Clinical Epidemiology, 2011
- Spontaneous Initiation of Atrial Fibrillation by Ectopic Beats Originating in the Pulmonary VeinsNew England Journal of Medicine, 1998