Nondestructive Measurement of Hemoglobin in Blood Bags Based on Multi-Pathlength VIS-NIR Spectroscopy
Open Access
- 2 February 2018
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 2204
Abstract
Hemoglobin concentration is an indicator for assessing blood product quality. To measure hemoglobin concentration in blood products without damaging blood bags, we proposed a method based on visible-near infrared transmission spectroscopy. Complex optical properties of blood bag walls result in measurement irregularities. Analyses showed that the slope of the light intensity-pathlength curve was more robust to the influence of the blood bag wall. In this study, the transmission spectra of red blood cell suspensions at multiple optical pathlengths were obtained, and the slopes of logarithmic light intensity-pathlength curves were calculated through curve fitting. A nondestructive measurement of hemoglobin content was achieved by using a regression model correlating slope spectra and hemoglobin concentration. Sixty samples with hemoglobin concentrations ranging from 72 to 161 g/L were prepared. Among them, 40 samples were used as a calibration set, and the remaining 20 samples were used as a prediction set. The determination coefficient of the prediction set was 0.97, with a mean square error of 2.78 g/L. This result demonstrates that a non-destructive measurement of hemoglobin levels in blood bags can be achieved by multiple-pathlength transmission spectroscopy.Keywords
This publication has 14 references indexed in Scilit:
- Rapid detection and characterization of the major chemical constituents in Akebia quinata by high performance liquid chromatography coupled to electrospray ionization and quadrupole time-of-flight mass spectrometryAnalytical Methods, 2016
- Rapid identification of soil cadmium pollution risk at regional scale based on visible and near-infrared spectroscopyEnvironmental Pollution, 2015
- Evaluation of Sugar Content of Potatoes using Hyperspectral ImagingFood and Bioprocess Technology, 2015
- Use of the Color Spaces in Determining the Level of Hemolysis in Blood under Storage2015
- Review: Near Infrared Spectroscopy for Analysing Olive OilsJournal of Near Infrared Spectroscopy, 2014
- Honey Discrimination Using Visible and Near-Infrared SpectroscopyISRN Spectroscopy, 2012
- Composition Analysis of Scattering Liquids Based on Spatially Offset Visible-Near-Infrared SpectroscopyApplied Spectroscopy, 2012
- New Seeding Methodology for Gas Concentration MeasurementsApplied Spectroscopy, 2012
- A Sensor for the Non-invasive Determination of Hemoglobin in Sampling TubesIFMBE Proceedings, 2009
- A novel device for the non – invasive measurement of free hemoglobin in blood bags / Messgerät zur zerstörungsfreien Messung von freiem Hämoglobin in BlutkonservenBiomedical Engineering / Biomedizinische Technik, 2005