Donnan Membrane Approach: From Equilibrium to Dynamic Speciation
- 22 July 2006
- journal article
- research article
- Published by American Chemical Society (ACS) in Environmental Science & Technology
- Vol. 40 (17) , 5496-5501
Abstract
Metal ion toxicity is not simply related to the total concentration but to the free or labile metal ion concentration. One of the techniques that can measure the free metal ion concentration is the Donnan Membrane Technique (DMT). However, this method has limitations in terms of a relatively high detection limit (in relation to typical environmental concentrations) and a long equilibration time. We have therefore developed the Flux Donnan Membrane (FDM) Technique, which is a dynamic modification of the standard DMT with improved detection limits and a more rapid response. We show that experimental calibrations of metal ion transport in the FDM can be used to measure [M]free under conditions of either solution-controlled or membrane-controlled diffusive transport. The FDM was used to measure cobalt binding isotherms by a humic substance over a large range of free Co concentrations and pH.Keywords
This publication has 14 references indexed in Scilit:
- Permeation liquid membrane as a tool for monitoring bioavailable Pb in natural watersScience of The Total Environment, 2004
- Metal ions speciation in a soil and its solution: experimental data and model resultsGeoderma, 2003
- Generic NICA−Donnan Model Parameters for Metal-Ion Binding by Humic SubstancesEnvironmental Science & Technology, 2003
- Diffusional characteristics of hydrogels used in DGT and DET techniquesAnalytica Chimica Acta, 1999
- On lability of chemically heterogeneous systems: Complexes between trace metals and humic matterColloids and Surfaces A: Physicochemical and Engineering Aspects, 1999
- Ion binding to natural organic matter: competition, heterogeneity, stoichiometry and thermodynamic consistencyColloids and Surfaces A: Physicochemical and Engineering Aspects, 1999
- Lability of heavy metal species in aquatic humic substances characterized by ion exchange with cellulose phosphateTalanta, 1997
- Models for Association of Metal Ions with Heterogeneous Environmental Sorbents. 1. Complexation of Co(II) by Leonardite Humic Acid as a Function of pH and NaClO4 ConcentrationEnvironmental Science & Technology, 1995
- In situ speciation measurements of trace components in natural waters using thin-film gelsNature, 1994
- Equilibrium dialysis—ligand exchange: a novel method for determining conditional stability constants of radionuclide—humic acid complexesAnalytica Chimica Acta, 1992