Assessment of the accuracy of truebeam intrafraction motion review (IMR) system for prostate treatment guidance
- 13 May 2019
- journal article
- review article
- Published by Springer Nature in Australasian Physics & Engineering Sciences in Medicine
- Vol. 42 (2) , 585-598
Abstract
Intrafraction motion review (IMR), a real-time 2D, motion management feature of the Varian Truebeam™ incorporates triggered imaging, automatic fiducial marker detection and automatic beam hold. With the increasing adoption of high dose per fraction stereotactic body radiotherapy (SBRT) this system provides a potential means to ensure treatment accuracy. The goal of this study was therefore to investigate and quantify key performance characteristics of IMR for prostate treatment guidance. Phantom experiments were performed with a custom Computerized Imaging Reference Systems, Inc (CIRS) pelvis phantom with implanted gold seeds and the Hexamotion™ 5D motion platform. The system accuracy was assessed statically and under typical prostate motion trajectories. The IMR functionality and marker detectability was tested under different anatomical conditions and with different imaging acquisition modes. Imaging dose for triggered imaging modes was determined using an ionisation chamber based on IPEMB dose calibration protocol for kV energies. For zero displacement, the IMR demonstrated submillimeter agreement with the known position. Similarly, dynamic motion differences between the IMR reported position and 2D trajectory displacement were within 1 mm. Static displacement in the anterior direction was reported by IMR as sinusoidal motion on the x-axis (kV angle). The 2D nature of IMR limits the ability to detect motion out of the plane of the kV image detector. Using typical clinical imaging settings, imaging dose determined at the patient surface was 2.58 mGy/frame and the corresponding IMR displayed dose was 2.63 mGy/frame. The methodology used was able to quantify the accuracy of the IMR system. The IMR was able to accurately and consistently report fiducial positions within the limitations inherent of a 2D system. IMR is fully integrated with the Truebeam system with an easy to use and efficient workflow and is clinically beneficial especially within the context of SBRT.Keywords
Funding Information
- Varian Medical System
This publication has 15 references indexed in Scilit:
- Reduction of prostate intrafractional motion from shortening the treatment timePhysics in Medicine & Biology, 2013
- Kilovoltage Intrafraction Monitoring for Prostate Intensity Modulated Arc Therapy: First Clinical ResultsInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Online Image-based Monitoring of Soft-tissue Displacements for Radiation Therapy of the ProstateInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- Comparison of dose decrement from intrafraction motion for prone and supine prostate radiotherapyRadiotherapy and Oncology, 2012
- Measurement of patient imaging dose for real-time kilovoltage x-ray intrafraction tumour position monitoring in prostate patientsPhysics in Medicine & Biology, 2012
- Implementation of a New Method for Dynamic Multileaf Collimator Tracking of Prostate Motion in Arc Radiotherapy Using a Single kV ImagerInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target TrackingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- Prostate gland motion assessed with cine-magnetic resonance imaging (cine-MRI)International Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- Accuracy of a wireless localization system for radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2005
- The IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al - 4 mm Cu HVL; 10 - 300 kV generating potential)Physics in Medicine & Biology, 1996