Experimental Studies of CS Type UV Sterilizer for the Urban Sewage Treatment

Authors:

Abstract
By treating the secondary effluent of Sanbaotun sewage treatment plant in Fushun with the CS type UV Sterilizer, the experiment researches the influence on the removal rate which includes the factors of turbidity, chromaticity, initial E.coli concentration of raw water, UV dose. The results show that the turbidity does not influence on UV disinfection efficiency with the turbidity from 1.5NTU to 3.8NTU. In the low-dose UV disinfection process, the influent sewage turbidity should under 4NTU to ensure the disinfection efficiency. Low chromaticity does not affect the UV disinfection efficiency, with the influent sewage chromaticity is under 15 degrees.The initial E. coli has a certain impact on little doses of UV disinfection with the concentration from 175 × 104 A/ L to 230 × 104 A/ L, no impact on high doses of UV disinfection。