Accuracy and repeatability of fourier velocity encoded M‐mode and two‐dimensional cine phase contrast for pulse wave velocity measurement in the descending aorta
- 23 April 2010
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 31 (5) , 1185-1194
Abstract
Purpose: To assess the accuracy and repeatability of Fourier velocity encoded (FVE) M‐mode and two‐dimensional (2D) phase contrast with through‐plane velocity encoding (2D‐PC) for pulse wave velocity (PWV) evaluation in the descending aorta using five different analysis techniques. Materials and Methods: Accuracy experiments were conducted on a tubular human‐tissue‐mimicking phantom integrated into a flow simulator. The theoretical PWV value was derived from the Moens‐Korteweg equation after measurement of the tube elastic modulus by uniaxial tensile testing (PWV = 6.6 ± 0.7 m/s). Repeatability was assessed on 20 healthy volunteers undergoing three consecutive MR examinations. Results: FVE M‐mode PWV was more repeatable than 2D‐PC PWV independently of the analysis technique used. The early systolic fit (ESF) method, followed by the maximum of the first derivative (1st der.) method, was the most accurate (PWV = 6.8 ± 0.4 m/s and PWV = 7.0 ± 0.6 m/s, respectively) and repeatable (inter‐scan within‐subject variation δ = 0.096 and δ = 0.107, respectively) for FVE M‐mode. For 2D‐PC, the 1st der. method performed best in terms of accuracy (PWV = 6.8 ± 1.1 m/s), whereas the ESF algorithm was the most repeatable (δ = 0.386). Conclusion: FVE M‐mode allows rapid, accurate and repeatable central PWV evaluation when the ESF algorithm is used. 2D‐PC requires long scan times and can provide accurate although much less repeatable PWV measurements when the 1st der. method is used. J. Magn. Reson. Imaging 2010;31:1185–1194.Keywords
This publication has 34 references indexed in Scilit:
- A new method for the determination of aortic pulse wave velocity using cross‐correlation on 2D PCMR velocity dataJournal of Magnetic Resonance Imaging, 2008
- CARDIOVASCULAR RISK ASSESSMENT THROUGH TARGET ORGAN DAMAGE: ROLE OF CAROTID TO FEMORAL PULSE WAVE VELOCITYClinical and Experimental Pharmacology and Physiology, 2008
- AGE, HYPERTENSION AND ARTERIAL FUNCTIONClinical and Experimental Pharmacology and Physiology, 2007
- Heterogeneous remodelling of the ascending and descending aorta with ageJournal of Human Hypertension, 2007
- Aortic Pulse Wave Velocity and Carotid-Femoral Pulse Wave Velocity: Similarities and DiscrepanciesHypertension Research, 2007
- Aging and Arterial Structure-Function Relations2006
- Does Arterial Stiffness Predict Atherosclerotic Coronary Events?2006
- Evaluation of Carotid-Femoral Pulse Wave VelocityHypertension, 2005
- Errors in Estimating Propagation Distances in Pulse Wave VelocityHypertension, 2003
- Assessment of Arterial Distensibility by Automatic Pulse Wave Velocity MeasurementHypertension, 1995