Semiactive control strategy for a phase II smart base isolated benchmark building
- 30 July 2008
- journal article
- research article
- Published by Hindawi Limited in Structural Control and Health Monitoring
- Vol. 15 (5) , 673-696
Abstract
This paper presents a semiactive control strategy for the seismic protection of the phase II smart base isolated benchmark building subjected to near-fault earthquakes. Magnetorheological (MR) fluid dampers controlled by an optimal direct output feedback control algorithm with a voltage generator are used as semiactive control devices. The benchmark building is an eight-story base isolated building, and the superstructure is considered to be a linear elastic system with lateral–torsional behavior. To reduce the energy transmitted to the structure from the ground, a combination of linear and nonlinear bearings is installed at the base of the structure. It is difficult to design the controller for this benchmark problem because of the nonlinear behavior of the isolation members. Linear control theory is frequently applied to nonlinear structures because there are no appropriate and well-defined control theories that can consider general types of nonlinearities. Therefore, to improve control performance, the nonlinearities of the isolation members are considered indirectly with the linear control theory during the design process of the controllers for the MR dampers. Numerical simulation results under various earthquake inputs show that the proposed control strategy is effective in reducing the responses of the isolation members as well as the superstructure. Therefore, the proposed control system could be used as an improved control strategy for base isolated buildings subjected to near-fault earthquakes. Copyright © 2008 John Wiley & Sons, Ltd.Keywords
This publication has 13 references indexed in Scilit:
- Smart base-isolated benchmark building part IV: Phase II sample controllers for nonlinear isolation systemsStructural Control and Health Monitoring, 2008
- Smart base-isolated benchmark building. Part II: phase I sample controllers for linear isolation systemsStructural Control and Health Monitoring, 2005
- Smart base-isolated benchmark building Part III: a sample controller for bilinear isolationStructural Control and Health Monitoring, 2005
- Smart base-isolated benchmark building. Part I: problem definitionStructural Control and Health Monitoring, 2005
- A General Method for Semi-Active Feedback Control of Variable Friction DampersJournal of Intelligent Material Systems and Structures, 2004
- Design of Seismic Isolated Structures1999
- Phenomenological Model for Magnetorheological DampersJournal of Engineering Mechanics, 1997
- Seismic isolation design of the San Bernardino County Medical Center replacement projectThe Structural Design of Tall Buildings, 1996
- Optimal Direct Output Feedback of Structural ControlJournal of Engineering Mechanics, 1993
- Convergence of a numerical algorithm for calculating optimal output feedback gainsIEEE Transactions on Automatic Control, 1985