Modeling and Evaluation of a Novel Hybrid-Driven Compliant Hand Exoskeleton Based on Human-Machine Coupling Model
Open Access
- 16 November 2021
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 11 (22) , 10825
Abstract
This paper presents the modeling design method for a novel hybrid-driven compliant hand exoskeleton based on the human-machine coupling model for the patients who have requirements on training and assisting. Firstly, the human-machine coupling model is established based on the kinematics characteristics of human fingers and the Bernoulli beam formula. On this basis, the variable stiffness flexible hinge (VSFH) is used to drive the finger extension and the cable-driven mechanism is used to implement the movement of the finger flexion. Here, a hand orthosis is designed in the proposed hand exoskeleton to act as the base and maintain the function position of the hand for patients with hand dysfunction. Then, a final design prototype is fabricated to evaluate the proposed modeling method. In the end, a series of experiments based on the prototype is proceeded to evaluate its capabilities on stretching force for extension, bio-imitability, finger flexion capability, and fingertip force. The results show that the prototype has a significant improvement in all aspects of the ability mentioned above, and has good bionics. The proposed design method can be utilized to implement the rapid design of the hybrid-driven compliant hand exoskeleton with the changed requirements. The novel modeling method can be easily applied in personalized design in rehabilitation engineering.Keywords
Funding Information
- National Natural Science Foundation of China (61803265)
- Shanghai Municipal Commission of Science and Technology of China (20S31905400)
This publication has 32 references indexed in Scilit:
- Design and Evaluation of a Soft and Wearable Robotic Glove for Hand RehabilitationIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2016
- Studies about the use of semicircular beams as hinges in large deflection planar compliant mechanismsPrecision Engineering, 2014
- The functional range of motion of the finger jointsJournal of Hand Surgery (European Volume), 2014
- Changing patterns in the epidemiology of traumatic brain injuryNature Reviews Neurology, 2013
- Use of a Novel Robotic Interface to Study Finger Motor ControlAnnals of Biomedical Engineering, 2009
- A Pseudorigid-Body 3R Model for Determining Large Deflection of Cantilever Beams Subject to Tip LoadsJournal of Mechanisms and Robotics, 2009
- Robot-based hand motor therapy after strokeBrain, 2007
- A robot‐assisted study of intrinsic muscle regulation on proximal interphalangeal joint stiffness by varying metacarpophalangeal joint positionJournal of Orthopaedic Research, 2005
- Survey of the needs of patients with spinal cord injury: impact and priority for improvement in hand function in tetraplegicsSpinal Cord, 2004
- CHANGES IN STIFFNESS FOLLOWING SHORT- AND LONG-TERM APPLICATION OF STANDARD PHYSIOTHERAPEUTIC TECHNIQUESRheumatology, 1994