Migration of Silicone Rods
Authors:
- 1 April 1994
- journal article
- case report
- Published by SAGE Publications in Journal of Hand Surgery (European Volume)
- Vol. 19 (2) , 199-201
Abstract
Two cases of migration of silastic rods into the forearm after the first stage of flexor tendon grafting are reported. A CT scan shows the rods well if they are not visible on a plain X-ray. Possible factors involved in distal detachment of the rods are the composition of the tendon spacer, method of distal fixation, method of proximal fixation and the time between the stages of reconstruction.Keywords
This publication has 9 references indexed in Scilit:
- A second-stage flexor tendon reconstruction after 18 yearsThe Journal of Hand Surgery, 1991
- The migrating tendon spacerBritish Journal of Plastic Surgery, 1991
- Active tendon implants in flexor tendon reconstructionThe Journal of Hand Surgery, 1988
- Two-stage flexor-tendon reconstruction. Ten-year experience.Journal of Bone and Joint Surgery, 1986
- Staged Tendon ReconstructionHand Clinics, 1985
- Staged flexor tendon reconstructionThe Journal of Hand Surgery, 1983
- An evaluation of the two-stage flexor tendon reconstruction techniqueThe Journal of Hand Surgery, 1983
- The role of flexor tenolysis in the palm and digitsThe Journal of Hand Surgery, 1977
- A Review of 100 Flexor Tendon Reconstructions with ProsthesisHand, 1977