Stereotactic coordinates associated with facial musculature contraction during high-frequency stimulation of the subthalamic nucleus
- 1 June 2009
- journal article
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery
- Vol. 110 (6) , 1317-1321
Abstract
High-frequency stimulation of the subthalamic nucleus (STN) in patients with parkinsonian symptoms is often used to ameliorate debilitating motor symptoms associated with this condition. However, individual variability in the shape and orientation of this relatively small nucleus results in multiple side effects related to the spread of electrical current to surrounding structures. Specifically, contraction of the muscles of facial expression is noted in a small percentage of patients, although the precise mechanism remains poorly understood. Facial muscle contraction was triggered by high-frequency stimulation of 49 contacts in 18 patients undergoing deep brain stimulation of the STN. The mean coordinates of these individual contacts relative to the anterior commissure-posterior commissure midpoint (also called the midcommissural point) were calculated to determine the location or structure(s) most often associated with facial contraction during physiological macrostimulation. The x, y, and z coordinates associated with contraction of the facial musculature were found to be 11.52, 1.29, and 1.15 mm lateral, posterior, and inferior to the midcommissural point, respectively. This location, along the lateral-anterior-superior border of the STN, may allow for the spread of electrical current to the fields of Forel, zona incerta, and/or descending corticospinal/corticobulbar tracts. Because stimulation of corticobulbar tracts produces similar findings, these results are best explained by the spread of electrical current to nearby internal capsule axons coursing lateral to the STN. Thus, if intraoperative deep brain stimulation lead testing results in facial musculature contraction, placement of the electrode in a more medial, posterior position may reduce the amount of current spread to corticobulbar fibers and resolve this side effect.Keywords
This publication has 16 references indexed in Scilit:
- Motor responses of muscles supplied by cranial nerves to subthalamic nucleus deep brain stimuliBrain, 2006
- High-Frequency Stimulation of the Subthalamic Nucleus for the Treatment of Parkinsonʼs Disease-A Team PerspectiveJournal of Neuroscience Nursing, 2004
- Electric field and stimulating influence generated by deep brain stimulation of the subthalamic nucleusClinical Neurophysiology, 2004
- The subthalamic nucleus in the context of movement disordersBrain, 2004
- Deep brain stimulation of the subthalamic nucleus: anatomical, neurophysiological, and outcome correlations with the effects of stimulationJournal of Neurology, Neurosurgery & Psychiatry, 2002
- Modeling the effects of electric fields on nerve fibers: influence of tissue electrical propertiesIEEE Transactions on Biomedical Engineering, 1999
- Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matterExperimental Brain Research, 1998
- Axons, but not cell bodies, are activated by electrical stimulation in cortical gray matterExperimental Brain Research, 1998
- Chronic electrical stimulation of the ventralis intermedius nucleus of the thalamus as a treatment of movement disordersJournal of Neurosurgery, 1996
- Effective stimulation distance for current from macroelectrodesExperimental Neurology, 1986