Comparison of the accuracy of the hemocue glucose analyzer with the Yellow Springs Instrument glucose oxidase analyzer, particularly in hypoglycemia
Authors:
- Alexander D M StorkASAlexander D M Stork
- Hans KempermanHKHans Kemperman
- D Willem ErkelensDED Willem Erkelens
- Thiemo F VenemanTVThiemo F Veneman
- 1 August 2005
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in European Journal of Endocrinology
- Vol. 153 (2) , 275-281
Abstract
Objective: We aimed to assess the accuracy of the HemoCue Beta-glucose analyzer (HemoCue) and its correlation with the Yellow Springs Instrument (YSI 2300 STAT; YSI) glucose oxidase analyzer, in particular for hypoglycemic values. Design and methods: Samples were taken from 24 volunteers during hyperinsulinemic glucose clamp studies. Glucose concentrations were determined immediately with the HemoCue in whole blood and with the YSI in plasma from the same sample. After correction for the difference between whole blood and plasma, the paired plasma glucose concentrations were analyzed with various statistical methods. Results: A total of 500 paired glucose values were obtained, 209 of which were in the hypoglycemic range. Mean±s.e. values were 4.85±0.004 mmol/l for the HemoCue (range 1.87–16.17) and 4.81±0.004 mmol/l for the YSI (range 1.88–15.00; P = 0.80). In the hypoglycemic region, values were 3.26±0.004 mmol/l for the HemoCue (range 1.87–5.17) and 3.22±0.003 mmol/l for the YSI (range 1.88–4.20; P = 0.59). Regression analyses were HemoCue = 1.019(YSI) −0.0577 mmol/l, with r = 0.9787 for all values; for hypoglycemic values the HemoCue = 1.1169(YSI) −0.3393 mmol/l, with r = 0.8798. Using Altman’s residual plot, the difference was 0.03±0.0009 mmol/l, with 18 (3.6%) paired values outside the 95% limits of agreement (−0.82 to 0.89 mmol/l). In the hypoglycemic range, the difference was 0.04±0.001 mmol/l, with six (2.9%) values outside the 95% limits of agreement (−0.71 to 0.79 mmol/l). In error grid analysis, one value was in zone D (0.2%) and five values (1%) were in zone B; 98.8% were within zone A. Conclusions: Determination of glucose with the HemoCue system had very good correlation with the YSI system in a broad range of glycemia and also for hypoglycemic values. We believe that these methods can be used interchangeably for research and clinical purposes in adults.Keywords
This publication has 33 references indexed in Scilit:
- Evaluation of Roche Accu-Chek Go and Medisense Optium blood glucose metersClinica Chimica Acta, 2005
- Evaluation of a glucose meter against analytical quality specifications for hospital useClinica Chimica Acta, 2004
- Performance Evaluation of Blood Glucose Monitoring DevicesDiabetes Technology & Therapeutics, 2003
- Comparison of Several Point-of-Care Testing (POCT) Glucometers with an Established Laboratory Procedure for the Diagnosis of Type 2 Diabetes Using the Discordance Rate. A New Statistical ApproachClinical Chemistry and Laboratory Medicine (CCLM), 2003
- Intensive Insulin Therapy in Critically Ill PatientsThe New England journal of medicine, 2001
- Metabolic Modulation of Acute Myocardial InfarctionCirculation, 1998
- Report of the Expert Committee on the Diagnosis and Classification of Diabetes MellitusDiabetes Care, 1997
- Accuracy of home blood glucose meters during hypoglycemiaDiabetes Care, 1996
- How accurate are home blood-glucose meters with special respect to the low glycemic range?Diabetes Research and Clinical Practice, 1993
- Evaluating Clinical Accuracy of Systems for Self-Monitoring of Blood GlucoseDiabetes Care, 1987