Depth of interaction decoding of a continuous crystal detector module
Authors:
- 29 March 2007
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 52 (8) , 2213-2228
Abstract
We present a clustering method to extract the depth of interaction (DOI) information from an 8 mm thick crystal version of our continuous miniature crystal element (cMiCE) small animal PET detector. This clustering method, based on the maximum-likelihood (ML) method, can effectively build look-up tables (LUT) for different DOI regions. Combined with our statistics-based positioning (SBP) method, which uses a LUT searching algorithm based on the ML method and two-dimensional mean-variance LUTs of light responses from each photomultiplier channel with respect to different gamma ray interaction positions, the position of interaction and DOI can be estimated simultaneously. Data simulated using DETECT2000 were used to help validate our approach. An experiment using our cMiCE detector was designed to evaluate the performance. Two and four DOI region clustering were applied to the simulated data. Two DOI regions were used for the experimental data. The misclassification rate for simulated data is about 3.5% for two DOI regions and 10.2% for four DOI regions. For the experimental data, the rate is estimated to be approximately 25%. By using multi-DOI LUTs, we also observed improvement of the detector spatial resolution, especially for the corner region of the crystal. These results show that our ML clustering method is a consistent and reliable way to characterize DOI in a continuous crystal detector without requiring any modifications to the crystal or detector front end electronics. The ability to characterize the depth-dependent light response function from measured data is a major step forward in developing practical detectors with DOI positioning capability.Keywords
This publication has 18 references indexed in Scilit:
- Performance Comparisons of Continuous Miniature Crystal Element (cMiCE) DetectorsIEEE Transactions on Nuclear Science, 2006
- Investigation of detector light response modeling for a thick continuous slab detector2005
- Depth of /spl gamma/-ray interaction within continuous crystals from the width of its scintillation light-distributionIEEE Transactions on Nuclear Science, 2005
- Evaluation of a prototype small-animal PET detector with depth-of-interaction encodingIEEE Transactions on Nuclear Science, 2004
- Sudbury neutrino observatory neutral current detector acquisition software overviewIEEE Transactions on Nuclear Science, 2004
- A novel PET detector block with three-dimensional hit position encodingIEEE Transactions on Nuclear Science, 2004
- cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning schemeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Design of a depth of interaction (DOI) PET detector moduleIEEE Transactions on Nuclear Science, 1998
- Simulating the performances of an LSO based position encoding detector for PETIEEE Transactions on Nuclear Science, 1997
- Light collection in scintillation detector composites for neutron detectionIEEE Transactions on Nuclear Science, 1988