An improved design of a passive sampler for polar organic compounds based on diffusion in agarose hydrogel
Authors:
- 30 March 2019
- journal article
- research article
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 26 (15) , 15273-15284
Abstract
Passive samplers based on diffusive gradients in thin hydrogel films (DGT) were recently modified for sampling of polar organic compounds in water. However, since the sampling rates of the commonly used DGT design with the surface area of 3.1 cm2 are low, we propose to increase them by applying a two-sided design with a larger sampling surface area of 22.7 cm2. The sampler design consists of two sorptive hydrogel disks compressed between two diffusive hydrogel disk layers strengthened by nylon netting and held together by two stainless steel rings. Sorbent/water distribution coefficients (KSW) were determined, and the sampler was calibrated for monitoring 11 perfluoroalkyl substances and 12 pharmaceuticals and personal care products in water at laboratory conditions using a closed system with artificial flow generated by submersible pumps. A field performance test was conducted at five locations in the Morava River basin in Czech Republic. The median value of laboratory-derived sampling rates was 43 mL day−1 with extreme values of 2 mL day−1 and 90 mL day−1 for perfluorotridecanoic and perfluoroheptanoic acids, respectively. The log KSW values of tested compounds ranged from 3.18 to 5.47 L kg−1, and the estimated halftime to attain sampler-water equilibrium ranged from 2 days to more than 28 days, which is the maximum recommended exposure period, considering potential issues with the stability of hydrogel. The sampler can be used for assessment of spatial trends as well as estimation of aqueous concentration of investigated polar compounds.Keywords
Funding Information
- FP7-ENV-2013 (603437)
- Ministerstvo Školství, Mládeže a Tělovýchovy (LM2015051)
- European Structural and Investment Funds, Operational Programme Research, Development, Education (CZ.02.1.01/0.0/0.0/16_013/0001761)
This publication has 40 references indexed in Scilit:
- Levels and distribution of dissolved hydrophobic organic contaminants in the Morava river in Zlín district, Czech Republic as derived from their accumulation in silicone rubber passive samplersEnvironmental Pollution, 2012
- An Improved Method for Estimating in Situ Sampling Rates of Nonpolar Passive SamplersEnvironmental Science & Technology, 2010
- Calibration of Silicone Rubber Passive Samplers: Experimental and Modeled Relations between Sampling Rate and Compound PropertiesEnvironmental Science & Technology, 2009
- A novel method for the in situ calibration of flow effects on a phosphate passive samplerJournal of Environmental Monitoring, 2009
- Performance of the Chemcatcher® passive sampler when used to monitor 10 polar and semi-polar pesticides in 16 Central European streams, and comparison with two other sampling methodsWater Research, 2008
- Development of Polar Organic Integrative Samplers for Analysis of Pharmaceuticals in Aquatic SystemsAnalytical Chemistry, 2007
- Field Trial of Contaminant Groundwater Monitoring: Comparing Time-Integrating Ceramic Dosimeters and Conventional Water SamplingEnvironmental Science & Technology, 2003
- Passive sampling for long-term monitoring of organic pollutants in waterTrAC Trends in Analytical Chemistry, 2000
- Performance Characteristics of Diffusion Gradients in Thin Films for the in Situ Measurement of Trace Metals in Aqueous SolutionAnalytical Chemistry, 1995
- In situ speciation measurements of trace components in natural waters using thin-film gelsNature, 1994