ACTIVE SILICONE OIL REMOVAL WITH A MODIFIED VACUUM SYRINGE
Authors:
- 1 January 2012
- journal article
- case report
- Published by Wolters Kluwer Health in RETINAL Cases & Brief Reports
- Vol. 6 (4) , 396-399
Abstract
Purpose: At present, the number of clinical indications for the use of silicone oil (SO) has increased in intraocular surgery because of the advent of new techniques in vitreoretinal surgery, availability of better quality oils, and greater experience in its use. Consequently, the number of procedures for SO removal has increased, and support technologies for these procedures are always a concern. Methods: A simple active technique for SO removal based on a 5-mL standard syringe with an 18G cannula was developed. The oil is suctioned into the syringe by the pulling effect of a spring assembled along the axis of the piston. No abrupt change in the intraocular pressure is produced because of the oil viscosity and the reduced diameter of the cannula. Results: A technique for SO removal that has been used successfully during the past 7 years is presented in this article. During the 7-year period, 234 SO removals were performed without any complication or device failure. Using the present method, the average time for SO removal was 4 minutes. Conclusion: The average extraction time with the technique is 4 minutes, which is in the range of other active techniques, and it is faster than passive methods that are performed between 8 and 9 minutes. The technique is in line with the advantages of more elaborated active methods without using complex technology. It is considered to be highly successful and easy to implement.Keywords
This publication has 11 references indexed in Scilit:
- An Elementary and Effective Method for Silicone Oil RemovalRetina, 2010
- REMOVAL OF SILICONE OIL WITH 25-GAUGE TRANSCONJUNCTIVAL SUTURELESS VITRECTOMY SYSTEMRetina, 2007
- Outcomes of Complex Retinal Detachment Repair Using 1000- vs 5000-Centistoke Silicone OilArchives of Ophthalmology (1950), 2005
- Removal of silicone oil from aphakia: Use of a self-sealing corneal incisionAmerican Journal of Ophthalmology, 2004
- COMPARISON OF SILICONE OIL REMOVAL WITH PASSIVE DRAINAGE ALONE VERSUS PASSIVE DRAINAGE COMBINED WITH AIR–FLUID EXCHANGERetina, 2002
- SILICONE OIL REMOVAL USING VITRECTOMY MACHINE:Retina, 2001
- Outcome after silicone oil removalBritish Journal of Ophthalmology, 2001
- Retinal redetachment after removal of intraocular silicone oil tamponadeBritish Journal of Ophthalmology, 2001
- Silicone oil in the repair of complex retinal detachmentsOphthalmology, 1998
- Vitrectomy With Silicone Oil or Long-Acting Gas in Eyes With Severe Proliferative Vitreoretinopathy: Results of Additional and Long-term Follow-upArchives of Ophthalmology (1950), 1997