Deep learning MRI halves scan time and preserves image quality across routine neuroradiologic examinations
Open Access
- 23 August 2025
- journal article
- research article
- Published by Oxford University Press (OUP) in Radiology Advances
- Vol. 2 (5) , umaf029
Abstract
Background: Magnetic resonance imaging (MRI) is a cornerstone of neuroimaging but is limited by lengthy acquisition times, which can lead to motion artifacts, patient discomfort, and delayed care. Deep learning reconstruction is an emerging technology that can offer image acquisition acceleration while maintaining image quality. Purpose: To compare image quality and acquisition efficiency between deep learning–accelerated vs conventional MRI (C-MRI) across a spectrum of routine neuroradiologic examinations. Materials and Methods: In this single-center retrospective study, 26 patients underwent imaging with a commercially available, FDA-cleared deep learning-accelerated MRI reconstruction algorithm (Deep Resolve, Siemens Healthineers), and C-MRI on a Siemens 3 T MAGNETOM Vida scanner between October 24 and November 14, 2023. A total of 113 sequence pairs were acquired across multiple body parts (brain [n = 28], cervical spine [n = 24], thoracic spine [n = 16], lumbar spine [n = 14], internal auditory canals [n = 5], sella [n = 5], neck [n = 5], temporomandibular joints [n = 6], brachial plexus [n = 4], and orbits [n = 6]) and sequences (T2 [n = 38], T1 [n = 30], short tau inversion recovery [n = 21], T1 post-contrast [n = 17], T2 fluid attenuated inversion recovery [n = 5], and proton density [n = 2]) and evaluated by 4 neuroradiologists blinded to the acquisition method for image quality using a 5-point Likert scale. Acquisition parameters were extracted from Digital Imaging and Communications in Medicine (DICOM) metadata and statistically compared. Rater preferences and interrater reliability were assessed using nonparametric tests and intraclass correlation coefficients. Results: Deep learning reduced mean scan time by 51.6% (95% CI: 45.7%–57.7%; from 110.8 seconds to 53.7 seconds; P < .001). Image quality assessments using a Likert scale showed scores slightly above neutral for signal-to-noise ratio (mean 3.51; 95% CI: 3.44–3.58), structural delineation (mean 3.51, 95% CI: 3.44–3.56), and overall image quality (mean 3.56, 95% CI: 3.49–3.63). However, poor interrater reliability (intraclass correlation [ICC] range: 0.06–0.33) showed that the observed differences were not consistent, indicating functional equivalence between conventional and deep learning images. Conclusion: Deep learning MRI enabled substantial scan time reductions while maintaining image quality.Keywords
This publication has 30 references indexed in Scilit:
- Deep learning–based reconstruction for acceleration of lumbar spine MRI: a prospective comparison with standard MRIEuropean Radiology, 2023
- Fast high-quality MRI protocol of the lumbar spine with deep learning-based algorithm: an image quality and scanning time comparison with standard protocolSkeletal Radiology, 2023
- Deep Learning Image Processing Enables 40% Faster Spinal MR Scans Which Match or Exceed Quality of Standard of CareClinical Neuroradiology, 2021
- Artificial Intelligence for MR Image Reconstruction: An Overview for CliniciansJournal of Magnetic Resonance Imaging, 2020
- MRI safety and devices: An update and expert consensusJournal of Magnetic Resonance Imaging, 2019
- Challenges in pediatric neuroimagingNeuroImage, 2019
- The Orthanc Ecosystem for Medical ImagingJournal of Digital Imaging, 2018
- KIKI‐net: cross‐domain convolutional neural networks for reconstructing undersampled magnetic resonance imagesMagnetic Resonance in Medicine, 2018
- MRI: Time Is Dose—and Money and VersatilityJournal of the American College of Radiology, 2010
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002