Intradiscal pressure measurements in normal discs, compressed discs and compressed discs treated with axial posterior disc distraction: an experimental study on the rabbit lumbar spine model
- 13 August 2005
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 15 (5) , 597-604
Abstract
Intervertebral disc (IVD) pressure measurement is an appropriate method for characterizing spinal loading conditions. However, there is no human or animal model that provides sufficient IVD pressure data. The aim of our study was to establish physiological pressure values in the rabbit lumbar spine and to determine whether temporary external disc compression and distraction were associated with pressure changes. Measurements were done using a microstructure-based fibreoptic sensor. Data were collected in five control rabbits (N, measurement lying prone at segment L3/4 at day 28), five rabbits with 28 days of axial compression (C, measurement at day 28) and three rabbits with 28 days of axial compression and following 28 days of axial distraction (D, measurement at day 56). Disc compression and distraction was verified by disc height in lateral radiographs. The controls (N) showed a level-related range between 0.25 MPa–0.45 MPa. The IVD pressure was highest at level L3/4 (0.42 MPa; range 0.38–0.45) with a decrease in both cranial and caudal adjacent segments. The result for C was a significant decrease in IVD pressure (0.31 MPa) when compared with controls (P=0.009). D showed slightly higher median IVD pressure (0.32 MPa) compared to C, but significantly lower levels when compared with N (P=0.037). Our results indicate a high range of physiological IVD pressure at different levels of the lumbar rabbit spine. Temporary disc compression reduces pressure when compared with controls. These data support the hypothesis that temporary external compression leads to moderate disc degeneration as a result of degradation of water-binding disc matrix or affected active pumping mechanisms of nutrients into the disc. A stabilization of IVD pressure in discs treated with temporary distraction was observed.Keywords
This publication has 31 references indexed in Scilit:
- Effects of unisegmental disc compression on adjacent segments: an in vivo animal modelEuropean Spine Journal, 2005
- New In Vivo Animal Model to Create Intervertebral Disc Degeneration and to Investigate the Effects of Therapeutic Strategies to Stimulate Disc RegenerationSpine, 2002
- 2002 SSE Award Competition in Basic Science: Expression of major matrix metalloproteinases is associated with intervertebral disc degradation and resorptionEuropean Spine Journal, 2002
- Matrix protein gene expression in intervertebral disc cells subjected to altered osmolarityBiochemical and Biophysical Research Communications, 2002
- Intradiscal pressure after repeat intradiscal injection of hypertonic saline: an experimental studyEuropean Spine Journal, 2001
- Effects of Chondroitinase ABC on Intradiscal Pressure in SheepSpine, 2001
- Matrix Metalloproteinases And AggrecanaseSpine, 2000
- 1998 Volvo Award Winner in Biomechanical StudiesSpine, 1998
- The Effect of Spinal Destabilization and Instrumentation on Lumbar Intradiscal PressureSpine, 1997
- Study of Correlation Between Intradiscal Pressure and Magnetic Resonance Imaging Data in Evaluation of Disc DegenerationSpine, 1991