Nanohydroxyapatite/polyamide 66 strut subsidence after one-level corpectomy: underlying mechanism and effect on cervical neurological function
Authors:
Open Access
- 14 August 2018
- journal article
- research article
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-7
Abstract
The aim of this study was to investigate n-HA/PA66 strut subsidence after one-level in Anterior cervical corpectomy decompression and fusion (ACCF) and its effect on treatment outcomes to better understand the underlying mechanism and related risk factors. In total, 56 patients undergoing ACCF using n-HA/PA66 struts were analysed retrospectively. After a 12-month follow-up, the height of the fused segments and fused intervertebral heights were measured, the neurological findings were evaluated using the Japanese Orthopedic Association (JOA) and axial pain was assessed using a Visual Analogue Scale(VAS). Subsidence was defined as a decrease in the height of the fused segments or the fused intervertebral body greater than 3 mm compared with that on postoperative day one, and all patients were assigned to the n-HA/PA66 strut subsidence and control groups. In total, 45 patients experienced n-HA/PA66 strut subsidence during the postoperative (3 ± 2.42/3.11 ± 2.01) months. No significant differences were observed in sex, age, hospitalization time, surgical haemorrhage,bone mineral density (BMD), or height in the n-HA/PA66 strut group. The JOA and VAS of neck pain in the control group improved more than those in the subsidence group, suggesting that subsidence might be correlated with poor improvement of neurological function. In conclusion, n-HA/PA66 strut subsidence is a common complication after ACCF, and the reduced height of the postoperative fused segments and the height reduction in the postoperative fused intervertebral bodies are independent risk factors of n-HA/PA66 strut subsidence.Keywords
This publication has 19 references indexed in Scilit:
- Long-term results of anterior cervical corpectomy and fusion with nano-hydroxyapatite/polyamide 66 strut for cervical spondylotic myelopathyScientific Reports, 2016
- Comparison of anterior cervical fusion by titanium mesh cage versus nano-hydroxyapatite/polyamide cage following single-level corpectomyInternational Orthopaedics, 2013
- A hollow cylindrical nano-hydroxyapatite/polyamide composite strut for cervical reconstruction after cervical corpectomyJournal of Clinical Neuroscience, 2012
- Anterior corpectomy and reconstruction with titanium mesh cage and dynamic cervical plate for cervical spondylotic myelopathy in elderly osteoporosis patientsArchives of orthopaedic and trauma surgery, 2011
- Titanium mesh cages (TMC) in spine surgeryEuropean Spine Journal, 2004
- Tissue engineering scaffold material of nano-apatite crystals and polyamide compositeEuropean Polymer Journal, 2004
- Development of biomimetic nano-hydroxyapatite/poly(hexamethylene adipamide) compositesBiomaterials, 2002
- Autograft versus Allograft in Degenerative Cervical DiseaseClinical Orthopaedics and Related Research, 2002
- Analysis of Titanium Mesh Cages in Adults With Minimum Two-Year Follow-UpSpine, 2000
- The Anterior Surgical Approach to the Cervical Spine: The Cloward Procedure: Past, Present, and FutureSpine, 1988