Abstract
This letter proposes a compact transmitter (Tx) for radiative nearfield wireless power transfer (WPT) to deep-implanted biomedical applications. A multiple-loop radiating plane and slotted-ring excitation ring structure are analyzed to generate a strong focused field inside the human tissue without using any controllable circuit. Meanwhile, an impedance matching network (IMN) is implemented on the Tx side to obtain the antenna operation and enhance the PTE at 1.9 GHz. Furthermore, a miniaturized receiver (Rx) is employed to verify the proposed Tx's performance. Experimental results show that our proposed WPT can supply power in a distance of up to $0.127\lambda _{0}$ with a PTE of -20.12 dB. Finally, our proposed WPT system is compared to other works in nearfield WPT to show our high PTE and compact antenna's dimensions.
Funding Information
  • National Research Foundation of Korea (NRF), Ministry of Science and ICT (NRF-2017R1A5A1015596)