On‐ and off‐resonance T1ρ MRI in acute cerebral ischemia of the rat
Open Access
- 31 December 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 49 (1) , 172-176
Abstract
The ability of on‐resonance T1ρ (T1ρ) and off‐resonance T1ρ (T) measurements to indicate acute cerebral ischemia in a rat model of transient middle cerebral artery (MCA) occlusion was investigated at 4.7 T. T1ρ was determined with B1 fields of 0.4, 0.8, and 1.6 G, and T with five offset frequencies (Δω) ranging from 0–7.5 kHz at B1 of 0.4 G, yielding effective B1 (Beff) from 0.4 to 1.8 G. Diffusion, T1, and T2 were also quantified. Both T1ρ and T acquired with Δo < 2.5 kHz showed positive contrast during the first hours of MCA occlusion in the ischemic tissue delineated by low diffusion. Interestingly, T contrast acquired with Δω > 2.5 kHz was clearly less sensitive to ischemic alterations, and developed with a delayed time course. This discrepancy is thought to be a consequence of the frequency dependency of cross‐relaxation during irradiation with spin‐lock pulses. Magn Reson Med 49:172–176, 2003.Keywords
Funding Information
- NIH (P41-RR08079)
- Research Council of Finland
- Sigrid Juselius Foundation
- Research Foundation of Leiras
- Saastamoinen Foundation
- North Savo Fund of Finnish Cultural Foundation
- Kuopio University Hospital (EVO program)
This publication has 17 references indexed in Scilit:
- Proton Exchange as a Relaxation Mechanism for T1 in the Rotating Frame in Native and Immobilized Protein SolutionsBiochemical and Biophysical Research Communications, 2001
- Cerebral T1ρ relaxation time increases immediately upon global ischemia in the rat independently of blood glucose and anoxic depolarizationMagnetic Resonance in Medicine, 2001
- Early Detection of Irreversible Cerebral Ischemia in the Rat Using Dispersion of the Magnetic Resonance Imaging Relaxation Time, T1ρJournal of Cerebral Blood Flow & Metabolism, 2000
- Quantitative magnetic resonance imaging assessment of cerebral ischemia in rat using on-resonance T1 in the rotating frameMagnetic Resonance in Medicine, 1999
- Magnetic Resonance Imaging of Acute StrokeJournal of Cerebral Blood Flow & Metabolism, 1998
- Off‐resonance spin locking for MR imagingMagnetic Resonance in Medicine, 1994
- Spin locking for magnetic resonance imaging with application to human breastMagnetic Resonance in Medicine, 1989
- Reversible middle cerebral artery occlusion without craniectomy in rats.Stroke, 1989
- A Method for Tlp ImagingJournal of Computer Assisted Tomography, 1985
- Spin-Lattice Relaxation in the Rotating Frame: Weak-Collision CasePhysical Review B, 1966