Prevention of urethral stricture in insertion of an inflatable penile prosthesis
Authors:
- 5 February 2008
- journal article
- Published by Wiley in International Journal of Urology
- Vol. 15 (2) , 162-165
Abstract
Objective: The aim of this study was to find the mechanism that causes urethral stricture with a view to preventing its occurrence after implantation of a three‐piece inflatable penile prosthesis.Methods: When implanting a three‐piece inflatable penile prosthesis, we draw two longitudinal lines parallel to the long axis of the proximal cylinder and the tubing leading from each cylinder into the cavernosal space, to prevent 360 degree rotation of the cylinder.Results: From September 1993 to February 2007, a total 86 three‐piece penile prosthesis implantations were carried out in 70 patients. Urethral stricture occurred in 5.8% (5/86) of the prosthesis operations. Fifteen three‐piece penile prosthesis reinsertions were carried out in 17.4% (15/86) of the prosthesis recipients.Conclusions: A successful outcome was achieved in the patients who received penile implantation with the three‐piece penile prosthesis that were marked with longitudinal lines. The rotation of the cylinder may cause compression on the urethra from the tubing leading from the cylinder or pump crossing over the urethra and resulting in urethral stricture. The drawing of longitudinal lines at the proximal cylinder and tubing leading from the cylinder could prevent the urethral stricture induced by tubes that are twisted by rotation of the cylinder.Keywords
This publication has 20 references indexed in Scilit:
- Upsizing of Inflatable Penile Implant Cylinders in Patients with Corporal FibrosisThe Journal of Sexual Medicine, 2006
- The Hydrophilic-Coated Inflatable Penile Prosthesis: 1-Year ExperienceThe Journal of Sexual Medicine, 2004
- The Penile Implant for Erectile DysfunctionThe Journal of Sexual Medicine, 2004
- EFFICACY OF ANTIBIOTIC IMPREGNATION OF INFLATABLE PENILE PROSTHESES IN DECREASING INFECTION IN ORIGINAL IMPLANTSJournal of Urology, 2004
- Penile prosthesis infectionsInternational Journal Of Impotence Research, 2001
- MECHANICAL RELIABILITY OF THE AMS 700CXM INFLATABLE PENILE PROSTHESIS FOR THE TREATMENT OF MALE ERECTILE DYSFUNCTIONJournal of Urology, 2001
- MECHANICAL RELIABILITY OF THE AMS 700CXM INFLATABLE PENILE PROSTHESIS FOR THE TREATMENT OF MALE ERECTILE DYSFUNCTIONJournal of Urology, 2001
- EFFICACY, SAFETY AND PATIENT SATISFACTION OUTCOMES OF THE AMS 700CX INFLATABLE PENILE PROSTHESIS: RESULTS OF A LONG-TERM MULTICENTER STUDYJournal of Urology, 2000
- AMS Three–Piece Inflatable Implants for Erectile Dysfunction: A Long–Term Multi–Institutional Study in 200 Consecutive PatientsEuropean Urology, 2000
- Safety and Efficacy Outcome of Mentor Alpha-1 Inflatable Penile Prosthesis Implantation for Impotence TreatmentJournal of Urology, 1997